Miller M-25M Manuale d'uso - Pagina 4
Sfoglia online o scarica il pdf Manuale d'uso per Accessori per la saldatura Miller M-25M. Miller M-25M 8. Air-cooled guns for gmaw and fcaw welding
6.
Replacing Switch And/Or Head Tube
1
Remove handle
locking nut.
4
Secure head
tube in vice.
6
For M-25 and M-25M models only, install existing
shock washer onto new head tube.
Hand-tighten head tube into cable connector.
Tools Needed:
3/4 in
OM-1035 Page 4
Y Turn Off welding power source
/wire feeder and disconnect gun.
5
Loosen jam nut.
Remove from vice
and turn head tube
out by hand.
8
Remove from vice. Reposition handle and install
switch housing. Secure with handle locking nut.
3
Slide handle.
2
Remove switch housing. Install new switch
and connect leads (polarity is not important).
Reassemble in reverse order. If replacing
head tube, continue to end of figure.
7
Place head tube in vice and tighten until
nuts are tight.
Ref. ST-800 795-C