6-11. Power Source Selection Menu

1
Power Source*
Left Display
Invision/XMT
MPa
35X MPa
Invision/XMT
MPa
450 MPa
Deltaweld 302
DELT
Deltaweld 452
DELT
Deltaweld 652
DELT
Dimension 302
DIM
Dimension NT
DIM
450
Dimension 452
DIM
Dimension 652
DIM
XMT 304
XMT
XMT 350
XMT
XMT 456
XMT
Invision 456
INV
Invision 354
INV
Optima
OPT
Custom
CUST
*For any power sources not listed, pick a matching voltage range or see Section 6-6 to set
Vmin and Vmax.
OM-289404 Page 22
2
Right Display
Voltage Range
35X
Vmin=10
450
Vmin=10
302
Vmin=10
452
Vmin=10
652
Vmin=10
302
Vmin=10
450
Vmin=10
452
Vmin=10
652
Vmin=10
304
Vmin=10
350
Vmin=10
456
Vmin=10
456
Vmin=10
354
Vmin=10
IMA
Vmin=10
PWR.S
Vmin=10
1 Left Display
2 Right Display
When the feeder is turned on, the
Power Source Selection Menu allows
the operator to select a default power
source. Selecting a default power
source, automatically sets the correct
Vmin and Vmax settings for adjusting
the output voltage of the power source.
First Time Feeder Is Turned On
The feeder automatically goes into the
Power Source Selection Menu. The feeder
displays "MPA" on the Left Display and
"35X" on the Right Display, meaning that a
MPa 350 amp machine is the default power
source, and has a voltage range of 10V as
Vmin and 38V as Vmax.
At power up, the operator has three seconds
to select a default power source from the list
shown on the display. Operator may scroll
through the list of power sources by using
the Adjust control. After selecting a power
source the operator has three seconds to
change to a different power source or begin
welding. When turning off the feeder, the de-
Vmax=38
fault power source will be retained.
Vmax=38
Next Time Feeder Is Turned On
The feeder will display the last selected de-
Vmax=32
fault power source. The operator has three
Vmax=38
seconds to select another power source, or
press the Program Button to exit the Power
Vmax=44
Source Selection Menu.
Vmax=32
Vmax=38
Vmax=38
Vmax=65
Vmax=35
Vmax=38
Vmax=38
Vmax=38
Vmax=35
Vmax=38
Vmax=38
OM-273244 Page 21