Sfoglia online o scarica il pdf Manuale per Inverter Miller Blue Star 185. Miller Blue Star 185 4. Generator power
Anche per Miller Blue Star 185: Manuale di applicazione (16 pagine)

Miller Blue Star 185 Manuale

Control Panel

1
2
3
4
Power Usage Guide
The power generator is designed to provide strong power while keeping the voltage within
10 percent of 120/240 V. 120/240 V ±10 percent is the range where tools and motors are
designed to operate. This increases tool/motor performance and tool/motor life.
Typical Contractor Tools
Starting
Tool
Watts
Hand Drill
1/4 inch
350
1/2 inch
600
Circular Saw
6-1/2 inch
500
8-1/4 inch
1,400
Table Saw (10 inch)
6,300
Band Saw (14 inch)
2,500
Air Compressor
1/2 hp
3,000
1-1/2 hp
8,200
Electric Chain Saw
1/2 hp, 12 inch
1,100
2 hp, 14 inch
1,100
Flood Lights
HID
125
Metal halide
313
Mercury
1,000
Vapor
1,250
Submersible Pump
600
(400 gph)
Centrifugal Pump
900
(900 gph)
High Pressure Washer
1/2 hp
3,150
1 hp
6,100
Wet and Dry Vac (1.7 hp)
900
Typical Farm Equipment
Running
Watts
Machine
Portable Conveyor (1/2 hp)
350
Farm Duty Motors
600
(e.g. conveyors, feed augers
air compressors)
500
1/3 hp
1,400
1-1/2 hp
1,800
Washer (2 gal/min.)
550 psi
1,100
700 psi
1,000
2,200
Typical Industrial Motors
1,100
1,100
Motor
100
250
Split Phase
1/8 hp
1,000
1/2 hp
200
Capacitor Start —
Induction Run
1/3 hp
500
1-1/2 hp
Capacitor Start —
Capacitor Run
950
1-1/2 hp
1,600
Fan
900
1/8 hp
1/2 hp
5
6
6
Typical Household
Appliance
Dishwasher
Cool dry
Hot dry
Electric Range
6-inch element
8-inch element
Starting
Running
Watts
Watts
Microwave Oven
(625 watts)
3,400
1,000
Refrigerator or Freezer
Automatic Washer
Clothes Dryer
1,720
720
Gas
8,200
2,200
Electric
Garage Door Opener
4,500
1,400
1/4 hp
6,100
1,600
1/2 hp
Furnace Fan (gas/fuel oil)
1/8 hp
1/6 hp
1/4 hp
1/3 hp
1/2 hp
Starting
Running
Watts
Watts
Lights
Radio
800
300
Well Pump
3,175
875
1/3 hp
1/2 hp
Sump Pump
2,020
720
1/3 hp
8,200
2,200
1/2 hp
Central Air Conditioner
10,000 Btu
8,100
2,000
20,000 Btu
24,000 Btu
1,000
400
32,000 Btu
3,500
1,100
40,000 Btu
1. Engine Hour Meter
2. 240 V Receptacle with
Circuit Breaker
3. Engine Control Switch with
Auto Idle
4. Choke Cable
5. 120 V GFCI Receptacles with
Circuit Breakers
5. Single-Range Amperage Control
6. Quick-Reference Parameter Chart
Starting
Running
Watts
Watts
1,400
700
1,400
1,450
0
1,500
0
2,100
800
625
2,200
700
2,300
1,150
1,800
700
1,800
5,750
1,100
550
1,400
725
500
300
750
500
1,000
600
1,400
700
2,350
875
0
As indicated
0
50–200
1,400
750
2,100
1,000
1,300
800
2,150
1,050
2,200
1,500
3,300
2,500
4,950
3,800
6,500
5,000
7,800
6,000
3