Burkert 8644 AirLINE Manuale di avvio rapido - Pagina 14

Sfoglia online o scarica il pdf Manuale di avvio rapido per Sistemi di controllo Burkert 8644 AirLINE. Burkert 8644 AirLINE 17.

NOTE!
For the plug-in connections the hose pipes must meet the following
requirements:
• Minimum hardness of 40 Shore D (in accordance with DIN
53505 or ISO 868);
• Outer diameter in accordance with DIN 73378 (max. permitted
deviation ± 0.1 mm of the nominal dimension);
• Burr-free, cut off at right angles and undamaged on the outer
diameter;
The hose pipes must be pressed all the way into the plug-in
connections.
7.1.2. Removing the plug-in connections
To detach the pipes, press in the thrust ring and pull out the hose
pipe.
7.1.3. P neumatic connections –
AirlINE standard
Fig. 11: Pneumatic connections - valve discs
14
Inscription areas
Working connections
for 5/2-way valves
Working connections
for 3/2-way valves
english
Type 8644
Installation
Procedure:
Depending on the version, plug the connections in the corre-
sponding working connections or screw them in.
Connection nipples can be used for threaded versions.
Inscription of the connections:
Label the inscription areas with the data of the valve
connections.
7.1.4. P neumatic connections –
AirLINE Quick
Fig. 12: Pneumatic connections – AirLINE Quick
Procedure:
Depending on the version, plug the connections in the corre-
sponding working connections.