Aquasana AQ-UV-10C Manuale d'uso
6
Add Gland Nut and Compression Spring
1. Hand tighten the Gland Nut over the Quartz
Sleeve onto the threaded end of the UV Reactor.
NOTE: DO NOT use tools for this step. It has
a positive stop to prevent over-tightening.
2. Insert the Compression Spring into the Quartz Sleeve.
NOTE: DO NOT install a UV Lamp inside the
Quartz Sleeve without the Compression
Spring in place.
7
Check For Leaks
When all plumbing connections have been completed, and you've allowed
proper time for glue to dry according to manufacturer instructions, slowly
turn on the water supply and check for leaks. Make sure the bypass valves
are functioning properly and that the water is flowing through the
UV Reactor.
Troubleshooting: The most common leak is from the O-Ring not making a
proper seal on the UV Reactor. For new installations, review steps 5 and 6.
If you experience leaks during this step while replacing your UV Lamp, drain
the UV Reactor, remove the O-Ring, dry it, and reapply silicon grease. Reinstall
the O-Ring ensuring that it is properly sealed against the UV Reactor and check
again for leaks.
8
Mount Controller
Mount the Controller to the wall above
the UV Reactor.
NOTE: Ensure that no moisture can
deposit on any of the connections.
Always mount the Controller vertically.
NOTE: DO NOT plug the Controller
power cord in before the last step.
INSTALLATION STEPS
2
1