Performance Data Sheet
Performance Data for the OptimH2O Whole House Water Filter - Model EQ-OPTM
Model
Replacement
Size
Micron Rating
NSF/ANSI 53
NSF/ANSI P473
Peak Flow %Reduction of
Lead and PFOA/PFOS
Minimum Operating
Temperature
Maximum Operating
Temperature
Minimum Operating
Pressure
Maximum Operating
Pressure
Electrical Requirements
Performance
The OptimH2O filter is IAPMO tested and certified to NSF/ANSI Standard 53 to reduce both soluble
and particulate forms of lead and cysts, and to NSF/ANSI Standard P473 to reduce perfluorooctanoic
acid (PFOA) and perfluorooctane sulfonate (PFOS). Actual performance is dependent on influent water
quality, flow rates, system design and applications. Your results may vary. Performance claims are
based on a complete system, including a filter, housing, and connection to a pressurized water source.
This filter must be operated according to the system's specifications in order to deliver the claimed
performance. It is essential to follow operational, maintenance, and filter replacement requirements, as
directed for each application, for this filter and system to perform correctly. Read the Manufacturer's
Performance Data Sheet accompanying the system and change the filter as suggested.
Internally tested Performance Data for the Aquasana Whole House Water Filter
Parameter
Chlorine, Chloramines Reduction
EQ-OPTM
EQ-OPTMR
8" x 42"
0.5
99.62% lead and cysts reduction
97.9% PFOA/PFOS reduction
8.54GPM (32.33LPM) @ 99.62% reduction
34 F / 1 C
120 F / 50 C
20 psig / 1.38 bar
125 psig / 8.6 bar
Grounded & Unswitched 115 V outlet and 3 AAA Batteries
The OptimH2O filter is IAPMO tested and certified
to NSF/ANSI Standard 53 to reduce both soluble
and particulate forms of lead and cysts, and to NSF/
ANSI Standard P473 to reduce perfluorooctanoic
acid (PFOA) and perfluorooctane sulfonate (PFOS).
Influent Challenge Chlorine
3 MG/L ±10%
Aquasana, Inc.
6310 Midway Rd, Haltom City, TX 76117
Overall % reduction
>90 %