Error messages:
RUB WINDOW Cx
SUNLIGHT Cx
CAL FAIL Cx
Cx: yyy Cerr
POWER LOST!
NO SPEED Cx
LENS PROBLEM Cx
REG.KOM ERR Cx
LOST Cx
Cx: yyy LOST
OVERRUN Cx
x may be 1,2,3 or 4. The counting is stopped for this channel. Clean all
surfaces between the light- source and sensor in the referred Registration
Unit. Then press the corresponding Cx key.
x may be 1,2,3 or 4. This is a warning, the counting is not stopped. Make
sure that the view of the lenses are not exposed to sunlight.
Then press the corresponding Cx key.
x may be 1,2,3 or 4. The Calibration was not correctly performed. A press
on the belonging channel button will view the number calculated.
Stop counting (N/S key). Restart and do a new calibration for this channel.
x may be 1,2,3 or 4, yyy is number. The calibration was not performed
correct, but the error was accepted. Press Stop
calibration for this channel.
Power disappeared during previous counting (not stopped with the 0/Stop
key). Press Enter to restart. When screen shows WEIGHT(g) Cx,
press Enter to resume counting.
x may be 1,2,3 or 4. This is a warning, counting is not stopped. The speed
calculations in the Registration Unit are having a problem.
This may be caused by too much water in a dry-counter, too much air in a
fullwater- counter, or dirt on the transparent pipe.
x may be 1,2,3 or 4. This is a warning, counting is not stopped. The lens at
the out-side is seeing dirt.
x may be 1,2,3 or 4. This is a warning, counting is not stopped. The
Control Unit receives incorrect data from the Registration Unit. This may be
caused by a faulty Unit (Registration Unit, Control Unit or cable), or
disturbance from external equipment.
x may be 1,2,3 or 4. The Control Unit does no longer receive data from the
Registration Unit.
x may be 1,2,3 or 4, yyy is number. The Control Unit does no longer receive
data from the Registration Unit, and the error was accepted.
x may be 1,2,3 or 4. The counting is stopped for Cx. The counting data
could not be processed fast enough and data has been lost.