Changing parameters:
The Control Unit uses several software parameters to control the counting. Depending on your
specific installation an operation of the system, some of these parameters may need to be adjusted by
the operator.
When the Control Unit asks for Weight for the first connected Registration Unit, it will accept special
commands. All commands are initiated with Delete key. Whenever Delete is pressed as the first
command a ? is shown. The next character will overwrite the ?. If Delete is pressed again the ? will
disappear.
To change parameters in setting #1, use the following code:
Delete < > 3 Enter
This code contains parameters which will set up how the Control Unit responds to other equipment.
To change parameters in setting #2, use the following code:
Delete < > 4 Enter
This code contains no parameters which will set up how the Control Unit responds to other
equipment.
The arrow buttons may be used to navigate between parameters in each code set.
To move to the next parameter in a code set, press > (6/> key) or N.
To move to the previous parameter in a code set, press < (5/< key).
To move to the first parameter in a code set, press ^ (7/^ key).
To move to the last parameter in a code set, press v (8/v key).
To leave a code set, press Stop, or at the last parameter in a set press N or edit it.
To edit a parameter, press Y, and then give the new value, followed by Enter. If Enter is pressed
without any value, the original value is kept.
Changing language:
WEIGHT(g) Cx:
If the language is set to Norwegian the display will show:
Answer Y, and set LNG= 1. Press Enter. The program versions are now
LNG=0 Ny?
displayed, and another press at Enter will show the serial number for the Control
Unit. Press Enter once more in order to proceed to WEIGHT.
In order to change language (English or Norwegian), or to look at program
versions and serial number, use this code: Delete < > 0 Enter