AquaScape 91011 Istruzioni e istruzioni per la manutenzione - Pagina 7

Sfoglia online o scarica il pdf Istruzioni e istruzioni per la manutenzione per Pompa dell'acqua AquaScape 91011. AquaScape 91011 16. Solids-handling pond pump
Anche per AquaScape 91011: Istruzioni e manutenzione (16 pagine), Manuale di istruzioni (16 pagine)

AquaScape 91011 Istruzioni e istruzioni per la manutenzione
• Pull off any debris stuck to the pump filter cage and/or use a
garden hose to spray off any debris stuck to the filter cage.
• Internal Pump Cleaning – if you have thoroughly cleaned
the filter cage screens and still have diminished flow rates,
then you will need to remove the pump from the lower cage
and inspect the impeller rotor assembly.
• Pull the cage release tabs outward to unlock the upper and
lower pump cages.
• With the cage tabs released, the upper filter cage can be
lifted to expose the pump.
www.aquascapeinc.com |
CAN 1-866-766-3426 |
• Remove the screws
securing the pump
restraining bracket,
allowing the pump to be
lifted from the lower cage.
• For easier pump access, pull the power cord free from the
strain relief.
• Remove the four screws that hold the water cover chamber
and inspect the impeller rotor assembly.
US 1-866-877-6637
7