AquaScape IONGEN SYSTEM G2 Manuale di istruzioni - Pagina 3
Sfoglia online o scarica il pdf Manuale di istruzioni per Sistemi di filtrazione dell'acqua AquaScape IONGEN SYSTEM G2. AquaScape IONGEN SYSTEM G2 20.
Contents
No.
Description
1.
IonGen
System Control Panel G2
™
2.
Flow Chamber G2
3.
Replaceable IonGen
Probe G2
™
4.
2" PVC Slip Fitting (2)
5.
1", 1.25", 1.5" Multi Hose Adapter (2)
6.
Plug-in Transformer
7.
Probe Holder
6
Safety Information
• Read this Instructions and Maintenance manual before
installing.
• Follow all local codes for installation.
• To reduce the risk of electric shock, connect only to a
properly grounded, ground fault interrupter (GFI).
• DO NOT immerse the IonGen
water.
WARNING: It is a violation of Federal law to use
this product in a manner inconsistent with its
labeling.
WARNING: This appliance must be grounded.
In the event of a malfunction or breakdown,
grounding will reduce the risk of electric
shock by providing a path of least resistance for electric
current. This appliance is equipped with a cord having an
appliance-grounding conductor and a grounding plug. The
plug must be plugged into an appropriate outlet that is
installed and grounded in accordance with all local codes
and ordinances.
☎
aquascapeinc.com |
CAN (866) 766-3426 |
1
Power
Ionization
IonGen ElectronicWaterClarifi e r
Power
Ionization
System Control Panel in
™
IonGen ElectronicWaterClarifi e r
☎
US (866) 877-6637
5
4
Includes (not pictured)
• Cu/Copper Test Kit (also sold separately as Item #96020)
• KH/Alkalinity Test Kit (also sold separately as Item #96019)
Also Available (not included)
• 25' Quick-Connect Extension Cable (sold separately as Item #98998)
WARNING: Improper connection of the
appliance-grounding conductor can result in
a risk of electric shock. Check with a qualified
electrician or service representative if you are
in doubt whether the appliance is properly grounded.
DO NOT modify the plug provided with the appliance; if
it will not fit the outlet, have a proper outlet installed by a
qualified technician.
IonGen System G2 Specifications
• Input Voltage: 120V
• Input Frequency: 60 Hz
• Output Voltage: 12V
• Output Current: 0.5A
• Plug-in Transformer: UL Listed, CSA Listed Rainproof
Class 2
• Flow Chamber: Injection Molded Plastic
• Probe material: 99% Copper
• Capacity: Up to 25,000 gallon water features
7
3
2
5
x 2
x 2
x 2
x 2
4
3