AquaScape AQUAFORCE 1000 Istruzioni e istruzioni per la manutenzione - Pagina 8

Sfoglia online o scarica il pdf Istruzioni e istruzioni per la manutenzione per Pompe per laghetti AquaScape AQUAFORCE 1000. AquaScape AQUAFORCE 1000 16. Solids-handling pond pump
Anche per AquaScape AQUAFORCE 1000: Istruzioni e manutenzione (16 pagine), Manuale di istruzioni (16 pagine)

AquaScape AQUAFORCE 1000 Istruzioni e istruzioni per la manutenzione
• If your rotor assembly impeller and internal pump body have
excessive scale build-up, clean with a mild acid, such as
white vinegar or non-abrasive calcium, lime and rust remover
product using a sponge or soft-bristled brush that won't
scratch the stainless steel. removing scale build-up will
allow your pump to run like new again.
rePlaCing the imPeller/rotor aSSembly
• For Model 5200: when
replacing the Aquaforce
5200 rotor-impeller
assembly into the pump
chamber, note the proper
orientation. the raised key
on the impeller face plate
should be lined up with
the groove in the pump
housing.
• For Models 1000 and 2700: the 1000 (pictured
below) and the 2700 models allow the impeller-rotor
assembly to be inserted into the pump body with no special
alignment guides needed.
PUMP FlANgE PiN
• AquaForce® 5200 ready for reassembly: the
water chamber cover will only fit back onto the pump
with the top of the tear-drop shapes lining up, along with
matching the hole in the cover with the pin on the face of the
pump motor flange.
PUMP FlANgE
PiN
8
gROOvE
®
RAiSEd kEy
PUMP wAtER
COvER HOlE
PUMP wAtER
COvER HOlE
US 1-866-877-6637 |
rePlaCing PumP in Cage
• Replace the pump into the lower cage and secure in
place with the brackets. Also replace the power cord in
the strain relief
• Reinstall filter cage and close all 5 snaps.

Winter Storage

• The pump can be run during freezing weather if desired but
should be removed if shutting down the pump for the winter.
Disconnect the threaded collar on the discharge fitting and
remove the pump from the pond (be careful not to lose the
flat rubber washer). Clean the pump and cage screens with
fresh water and store the pump in a frost-free location.

troubleShooting

• Reduced Water Flow
– pump or plumbing may be clogged. it may be necessary
to clean the pump cage screens and impeller.
• Pump Hums and Doesn't Push Water
– pump or plumbing may be clogged. it may be necessary
to clean the pump cage screens and impeller.
– remove the water chamber cover and inspect and clean
the impeller rotor assembly and internal pump body.
– Make sure nothing is blocking or wrapped around the
impeller.
– Make sure the pump is receiving the correct voltage.
• Pump Not Working
– the ground-fault circuit-interrupter (gfCi) may have tripped
– the pump is not receiving the correct voltage.
For more information about our company or products,
please visit our website at www.aquascapeinc.com
or call us at (US) 1-866-877-6637 (CAN) 1-866-766-3426
©2012 Aquascape, Inc. • All Worldwide Rights Reserved
CAN 1-866-766-3426 | www.aquascapeinc.com
91074.112011