• 24 V AC power supply connector kit (accessory)
Recommended specification of cable (wire)
Wire size
#24
(AWG),
(0.22 mm)
(0.33 mm)
stranded
wire
Length of
20 m
cable
{65.62 feet}
{98.43 feet}
Terminals of the power supply connector
Pin No.
Signal
1
24 V AC LIVE
2
24 V AC NEUTRAL
3
Ground
4
Not use
• How to assemble the power supply connector
Remove approx. 3 mm {1/8 inches} of the outer jacket of
the cable and twist the cable core to prevent the short cir-
cuit first.
Insert the tip of the cable into the point A of the contact,
and hold the cable using the cable clamp.
Approx. 3 mm {1/8 inches}
Upper
A
side
Contact
Insert
Procure either of the following tools for clamping.
Molex manual clamp tool:
57027-5000 (for UL1015), 57026-5000 (for UL1007)
After clamping the contact and the cable, insert the con-
tact properly into the power supply connector housing.
Upper side
Power supply connector housing (accessory)
Important:
• Conduct the electric conduit work after processing
the power supply connector and making sure that the
camera is operating normally.
#22
#20
#18
(0.52 mm)
(0.83 mm)
30 m
45 m
75 m
{147.64 feet}
{246.06 feet}
4
2
Cable
Cable
Contact
• Network cable
Connect a LAN cable (category 5e or better, STP*) to the
network connector.
* E model only
Important:
• Use all 4 pairs (8 pins) of the LAN cable.
• The maximum cable length is 100 m {328 feet}.
• Make sure that the PoE+ device in use is compliant
with IEEE802.3at standard.
• When connecting both of the 24 V AC power supply
and the PoE+ device for power supply, 24 V AC will
be used for power supply.
Depending on PoE+ (or PoE) devices, the power sup-
ply indicator may light or the network functions may
3
be unavailable.
1
In this case, disable the PoE+ (or PoE) settings. Refer
to the operating instructions of the PoE+ (or PoE)
device in use.
• Output cable for the monitor used for adjustment
Connect a coaxial cable (BNC) (only for checking if images
are displayed on the monitor).
This output is provided only for checking the adjustment
of the angular field of view on the video monitor when
installing the camera or when servicing.
Important:
• The monitor out connector for adjustment is provided
only for checking the adjustment of the angular field
of view on the video monitor when installing the cam-
era or when servicing. It is not provided for recording/
monitoring use.
• Black bands may appear at the top and bottom or
right and left of the screen. (That does not affect the
adjustment because the angular field of view is not
changed.)
• External I/O cable
Important:
• Input and output of the external I/O terminal 2 and 3
can be switched by configuring the setting. The
default of EXT I/O terminal 2 is "ALARM IN 2" and of
EXT I/O terminal 3 is "ALARM IN 3". It is possible to
determine whether or not to receive input from EXT
I/O terminal 2 and 3 (ALARM IN2, 3) by selecting
"Off", "Alarm input", "Alarm output" or "AUX output"
for "Terminal alarm 2" or "Terminal alarm 3" on the
[Alarm] tab on the "Alarm" page. Refer to the
Operating Instructions (included in the CD-ROM) for
further information.
• When using the EXT I/O terminals as the output termi-
nals, ensure they do not cause signal collision with
external signals.
23