AQUASYSTEM AMH1-25SUS Manuale operativo - Pagina 6
Sfoglia online o scarica il pdf Manuale operativo per Pompa dell'acqua AQUASYSTEM AMH1-25SUS. AQUASYSTEM AMH1-25SUS 12. Air-motor type centrifugal pump
Important Notices to use Air Motor
1. Compressed air should be kept under 0.6 MPa.
Use pure compressed air without dust and/or water etc.
2. Be sure always to use air-filter and lubricator,
so that the motor can keep normal rotation.
3. Be sure to apply a strainer,
so that inlet pipe will not suck slurry and/or foreign materials.
4. Apply proper hoses and valves with the sizes which are capable
enough to secure proper flow volumes.(More than 3/8)
5. Adjust the oil filling volume to the motor at the rate of 1 drop/minute.
※Be sure always to use Air-Filter/Lubricator
We recommend the below models (as optional product)
AIR-FILTER : CKD made Air-Filter : F-1000-8-W
LUBRICATOR : CKD made LUBRICATOR : L-1000-8-W
Specification Table
Types
Available Liquids
Max. viscosity
Max. pressure
Max.lifting height
Max. delivery volume (at 1cP)
Parts
Body
Material
Packing
Connection size
Compressor power
Driving system
Weight
AMH1-25FC
Gasoline,
Kerosene,
Light Oil,
Oil
2,000 cP
0.15 MPa
15 m (for pure water)
38 L/min.
AL,FC
PTFE
Rc1
Higher than 3HP
Radial piston motor Vane Pump
9.5 kg
5
AMH1-25SUS
Water,
Oil,Biodiesel,
Chemical Liquid,
Solvents
SUS
11 kg