AQUASYSTEM APDX1-25G Manuale operativo - Pagina 8

Sfoglia online o scarica il pdf Manuale operativo per Pompa dell'acqua AQUASYSTEM APDX1-25G. AQUASYSTEM APDX1-25G 16. Air pressure pump for drum can application

AQUASYSTEM APDX1-25G Manuale operativo

In the below case happens,

During the operation, when any unusual case happens, immediately stop the operation.
Please carefully check, in any of the below cases happens.
In case of "Discharging (OUT)",
If any foreign material is clogged in sucking pipe or hose.
If the compressed air is firmly connected.
No
Discharging
If a drum can is completely sealed.
at all
If a drum can and/or hose is not damaged.
If air valve and/or discharging valve is fully opened.
If any foreign material is clogged in sucking pipe.
If the pressure in a drum can is too low.
Make sure of the pressure with gauge (Specified Pressure: 0.025MPa)
Discharging
If the pressure of compressed air is not too low.
Volume is
If the valve is fully open
too small
If switching lever is turned enough, until it is stopped at "OUT" position.
If strainer is properly kept clean.
If the viscosity of liquid is too high.
A drum can is
If the pressure in a drum can is too high.
deformed
Make sure of the pressure with gauge(Specified Pressure: 0.025MPa)
If a drum can is strong enough.(Please read warning items on Safety
Clause in Operation Manual.
In case of "Sucking (IN)",
If any foreign material is clogged in sucking pipe or hose.
If compressed air is firmly connected.
No sucking
If a drum can is completely sealed.
at all
If a drum can and/or hose is not damaged.
If air valve and/or discharging valve is fully opened.
If the drum can or hose is not damaged?
If any foreign material is clogged in sucking pipe or hose.
Discharging
capacity is not
If switching lever is turned enough, until it is stopped at "IN" position.
strong enough
If strainer is properly kept clean. *
If the viscosity of liquid is too high.
A drum can is
If the pressure in a drum can is too high. Make sure of the pressure with gauge.
deformed
(Specified Pressure should be less than 0.6MPa)
If a drum can is strong enough.
(Please read warning items on Safety Clause in Operation Manual.)
*Strainer is placed in an air adjusting thread Always keep clean.【Refer to Photo-3】
In case anything abnormal is found or experienced, do not disassemble the product by
yourself. Immediately contact us or the shop you purchased.
7