Aquatec 8800 RO Booster Pump #92317

Installation Instructions

Please read these Operational and Installation Guidelines before installing the PAB8800 Series Booster Pump. If additional
help is needed, please consult the Factory.
CAUTION:
1. The pump is equipped with either a fixed or adjustable bypass valve which controls the maximum operating pressure.
In addition, never subject the pump to pressures above 125 PSI (8.5 bars).
2. Never operate the pump in harsh environment or hazardous atmosphere, since motor brush and switch may cause
electrical arcing.
3. Pumphead materials are designed for use with water only. Do not use with petroleum products.
4. As long as there is feed water pressure, the pump will not stop forward flow of water even if the motor is turned off. Be
sure the system has positive means of shutting off water supply.
5. Always consider electrical shock hazard when working with and handling electrical equipment. If uncertain, consult an
Electrician. Electrical wiring should only be done by a qualified Electrician per Local and State Electric Codes.
MOUNTING:
A. The pump should be mounted in a dry place and away from any source of heat. If an enclosure is used, special
provisions for cooling the motor may be necessary. Certain models may be ordered with a thermal protected motor.
B. Do not subject the Pump to extreme high or low (freezing) temperatures while in operation. (Operating ambient
temperatures range is 32°F to 115°F)
C. The pump may be mounted in any position. If "ceiling mounted", however, with the pump head upside down, air
entrapment may reduce the operational performance by up to 15%. Consult Aquatec for ceiling mount solutions.
PLUMBING:
A. We recommend use of flexible tubing with proper pressure rating.
B. Pump will prime only if all pressure is relieved from the outlet port.
C. It is recommended that an in-linen sediment filter (150 micron or 100 mesh) be installed at the inlet side to keep foreign
debris out of the system. Please consult your Aquatec catalog for an in-line filter.
D. Avoid any sharp bends which may crimp tubing and restrict flow. Use 90° elbow fittings if necessary. Aquatec provides
pumps with different kinds of fittings. Please consult the Factory for your needs.
E. The pump should always be mounted prior to the carbon pre-filter to prevent carbon particles from entering the pump
chambers and possibly causing clogging.
ELECTRICAL:
A. The PAB8800 series pumps are designed for continuous duty. If used for intermittent duty cycle, make sure that "off"
periods are great than 60 seconds. Consult the Factory for particular data and design criteria.
B. If a power supply used with the system and the supply is not furnished by Aquatec, it will need to be reviewed for correct
application and approval by Aquatec.
The basic 8800 pump consists of a pump and transformer unit. Systems may be supplied with other options: e.g. PSW
system pressurized shut-off switch. LPS low feed-water shut-off switch, TLC tank level controller or PAF membrane
auto-flush valve or PFR membrane auto-flush flow restrictor valve. Pumps are completely assembled, tested and ready
for immediate connection to your R.O. system.