Aquatec SWP-4000 Manuale d'uso - Pagina 4
Sfoglia online o scarica il pdf Manuale d'uso per Pompa dell'acqua Aquatec SWP-4000. Aquatec SWP-4000 12. Swp series solar electric submersible pump d.c. powered
Cable and splice:
Location of the solar panels should be close to the pump application for limited voltage drops through wire run lengths.
The suggested wire gauge is #10 AWG jacketed Submersible cable. It is important to make a quality watertight splice to
connect the electrical conducting wires to the submersible pump lead wires. Improper sealing of the splice may allow
water intrusion which will damage the pump motor and/or cause reduced pump performance.
Water Proof Wire Splice Kit
1
2
3, 4
Use general guidelines detailed by each manufacturer.
1) Place shrink sleeving on both wires of one cable end to be spliced.
2) Crimp connectors to join both cable ends.
3) Move shrink sleeving to center of connectors and apply heat starting from the middle and working towards the ends.
4) A seal is achieved when material flows from the ends of the tubes.
AQUATEC IMI-160, REV C, ECO# 6511, 3/16/15