HP 353803-B22 - StorageWorks Modular Smart Array 1000 SAN Starter Nota di rilascio - Pagina 4

Sfoglia online o scarica il pdf Nota di rilascio per Interruttore HP 353803-B22 - StorageWorks Modular Smart Array 1000 SAN Starter. HP 353803-B22 - StorageWorks Modular Smart Array 1000 SAN Starter 5. Storageworks modular smart array controller, cache, and battery replacement instructions
Anche per HP 353803-B22 - StorageWorks Modular Smart Array 1000 SAN Starter: Manuale di riferimento (48 pagine), Manuale di amministrazione (40 pagine), Nota di rilascio (13 pagine), Istruzioni per l'avvio rapido (8 pagine), Nota di rilascio (8 pagine), Nota di rilascio (8 pagine), Manuale di avvio rapido (7 pagine), Istruzioni per la sostituzione (4 pagine)

HP 353803-B22 - StorageWorks Modular Smart Array 1000 SAN Starter Nota di rilascio
MSA1000 firmware version 7.0
HP MPIO Basic DSM software version 1.3 or HP MPIO Full-Featured DSM software version 1.00.02
(requires VDS 1.1)
MSA Active-Passive:
MSA1500 firmware version 5.02
MSA1000 firmware version 4.48
HP MPIO Basic DSM software version 1.3

Installation instructions

See the following manuals provided with the software for installation instructions:
The HP StorageWorks Modular Smart Array FC VDS Hardware Provider administration guide
(T1634-96074, February 2007) covers preconfiguration, installation, and troubleshooting in
detail.
Important: Remove existing HP MSA FC VDS hardware provider software versions prior to 4.01.00 using
the Windows Add or Remove Programs control panel before you install the new software. Versions
4.01.00 and later can be updated automatically during installation.
To install:
Download the hardware provider InstallShield executable and run it. After installing, restart Virtual
Disk Service.
To run the hardware provider:
The hardware provider requires a client GUI or CLI. A CLI is freely available as part of the Windows
2003 Resource Kit. The utility diskraid.exe provides console-based access to the hardware provider.
To remove the hardware provider:
You can remove the hardware provider by using the hardware provider InstallShield Wizard or by using
the Windows Add or Remove Programs control panel.
Important clarification:
On pages 11 and 20 of the HP StorageWorks Modular Smart Array FC VDS Hardware Provider
administration guide (T1634-96074, February 2007), it is recommended that you create LUNs close to
the same size as the physical disk size to ensure there is no unusable space left over on the disk(s). If
you do use the VDS framework to make a LUN smaller than the physical disk size, you may be able to
use the remaining disk space by using a DiskRAID or DiskPart create command and specifying the
drive number as a parameter in the command. For example If you have three 36 GB drives totalling
108 GB and you create a LUN of 20 GB spanning all three disks, to create a LUN in the remaining
88 GB space, specify the three physical disk numbers as parameters. See the Microsoft DiskRAID or
DiskPart documentation for details about the create commands.
Support and feedback:
For support of the HP StorageWorks Modular Smart Array FC VDS Hardware Provider or HP
StorageWorks Modular Smart Array controllers, send e-mail to [email protected]. To provide feedback
or suggestions, send comments to [email protected].
Compatibility/Interoperability
The MSA VDS hardware provider does not support two concurrently running client applications
that use the VDS service. Running client applications concurrently may cause the hardware
provider to hang. If this occurs, take the following action:
1.
Close the client application.
2.
Stop the VDS service by typing net stop vds at the command line. (Click Start, click Run,
type command, type net stop vds in the command window, and press enter.)
4