HP StorageWorks 8/8 - SAN Switch Nota di rilascio
CRC errors did not match between portstatsshow and port-
errshow.
Under rare conditions, an HP StorageWorks DC SAN Backbone Dir-
ector panics during SAK IRNDUP when the software watchdog detects
an unexpected termination of the FICON CUP daemon (ficud).
User may need to change TI zone member in order to modify TI Zone
property (failover setting).
SW_RSCNs for RSCNs generated by attached nodes are not being
handled in McDATA Mode.
Legacy zone commands can be used to modify TI zones.
After hareboot, "Probing failed" on F_Port messages may be seen
on the HP StorageWorks 8/8, 8/24, 8/40, and 8/80 SAN switches.
HP StorageWorks 400 Multi-protocol Router panicked after TI zone
activation.
B-Series Multi-protocol Router blade faulted after overnight stress testing.
Received error message with high temperature (89) on edge HP Stor-
ageWorks DC SAN Backbone Director in fabric.
The portcfgnpivport CLI command will not toggle trunked slave
ports if the user disables NPIV configuration on that port.
Faulted (51) core blade due to POST failure, resulted from overnight
power cycle test.
After attempting cfgdisable on a system in native interopmode and
with default zoning set to all access and a large zoneset of at least
460 devices, the switch became faulty.
No F_RJT's being returned for class 2 frames that are not routable ac-
cording to a QoS/TI configuration.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Use portstatsshow to determine
whether there are CRC errors on a
link.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Use configupload/download to
change the TI zone, or modify the
member and the property (failover
disable/enable) together.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Do not configure an FCIP Tunnel.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
The user must manually toggle (en-
able/disable) the slave port to com-
plete the operation.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Disable the diagnostic POST, then
slotpoweroff on the faulted core
blade.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
HP StorageWorks Fabric OS 6.2.0b release notes