No RSCN sent for physical device offline/online.1
CRC error observed between HP StorageWorks 8/40 and 8/80 SAN
switches with a particular SFP type.
Fibre Channel FastWrite path does not recover after restoring DWDM
connection.
Console security feature causes process failure.
PORT RSCNs are sent to DPC (VIs & VTs) every time when the config-
uration changes, which is unrelated to VT/VI. This affects any applic-
ation that uses frame redirect zoning.
FICON tape Write Acceleration sent UC status to channel twice for
one UC from device side.
Various tape creation or restore process issues found with FICON tape.
Initiator does not log into target several hours into ISL failover stress
test that forces host path failover.
Trying to enable a LUN on a member node fails stating 'Specified
target not hosted by local node.'
Configdownload fails for fdd.* parameters from Fabric OS 6.1.1
to v6.2.0 through CAL.
With default zoning set to All Access, ACK frame with FC_type Exten-
ded Link can be dropped.
Fabric OS 6.2.0a fixes
The following table lists defects closed in the Fabric OS 6.2.0a firmware release.
Table 9 Fabric OS 6.2.0a closed defects
Closed defect summary
In a B2E routed environment, when the user executes the Pathinfo
command in BB querying for xlate domain, the switch may panic.
Some OS/HBA combinations take down the FC link when N_port-
generated RSCNs are delivered by switch with 0x08 (Fabric OS 6.1.1b
and 6.1.0g) or 0x20 (6.1.0x) as event qualifier. The fix reverts back
to Fabric OS 6.0 value of 0x00.
Switches slowly leaked memory over an extended period while being
managed by DCFM.
40
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
switchdisable/enable of the HP
StorageWorks 400 Multi-protocol
router allows the devices to see each
other
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Resubmit failed jobs.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Solution
Fixed in Fabric OS 6.2.0a.
Fixed in Fabric OS 6.2.0a.
Fixed in Fabric OS 6.2.0a.