HP StorageWorks Core Switch 2/64 Specifiche rapide - Pagina 12

Sfoglia online o scarica il pdf Specifiche rapide per Interruttore HP StorageWorks Core Switch 2/64. HP StorageWorks Core Switch 2/64 13. Director power cord advisory instruction
Anche per HP StorageWorks Core Switch 2/64: Nota di rilascio (27 pagine), Nota di rilascio (24 pagine), Nota di rilascio (20 pagine), Nota di rilascio (13 pagine), Nota di rilascio (11 pagine), Istruzioni (1 pagine)

HP StorageWorks Core Switch 2/64 Specifiche rapide
QuickSpecs

Technical Specifications

Fibre Channel ports
Fibre Channel ports
Fibre Channel ports
Fibre Channel ports
Control processor
Control processor
Control processor
Control processor
Scalability
Scalability
Scalability
Scalability
Performance
Performance
Performance
Performance
Certified maximum
Certified maximum
Certified maximum
Certified maximum
Interoperability
Interoperability
Interoperability
Interoperability
Switch core
Switch core
Switch core
Switch core
Fabric latency
Fabric latency
Fabric latency
Fabric latency
Hardware options
Hardware options
Hardware options
Hardware options
ISL Trunking
ISL Trunking
ISL Trunking
ISL Trunking
Aggregate bandwidth
Aggregate bandwidth
Aggregate bandwidth
Aggregate bandwidth
Switch latency
Switch latency
Switch latency
Switch latency
Maximum frame size
Maximum frame size
Maximum frame size
Maximum frame size
Frame buffers
Frame buffers
Frame buffers
Frame buffers
Classes of service
Classes of service
Classes of service
Classes of service
Port types
Port types
Port types
Port types
Data traffic types
Data traffic types
Data traffic types
Data traffic types
Media types
Media types
Media types
Media types
Laser
Laser
Laser
Laser
Fabric services
Fabric services
Fabric services
Fabric services
High Availability
High Availability
High Availability
High Availability
Management
Management
Management
Management
Management access
Management access
Management access
Management access
Diagnostics
Diagnostics
Diagnostics
Diagnostics
128 universal ports
Redundant (active/standby) control processor modules
Full fabric architecture:
http://h18006.www1.hp.com/products/storageworks/san/documentation.html
1.063 Gb line speed, full duplex; 2.125 Gb line speed, full duplex; auto-sensing of 1 Gb and 2 Gb
port speeds; optionally programmable to fixed port speed; speed matching between 1 Gb and 2 Gb
ports
Refer to SAN Design Guide
http://h18006.www1.hp.com/products/storageworks/san/documentation.html.
SAN Switch 8, SAN Switch 16, SAN Switch 8-EL, SAN Switch 16-EL, Integrated /32, Integrated /64 (not
currently supported).
Non-blocking
<2 µ sec. with no contention, cut-through routing
16-port blades, SFP media
Up to four 2.125 Gb ports per ISL trunk; to 8.5 Gb per ISL Trunk
512 Gb end-to-end
<2.1 µsec any port to any port at 2 Gb, cut-through routing
2112-byte payload
108 per 4-port group, dynamically allocated
Class 2, Class 3, Class F (inter-switch frames)
FL_port, F_port, and E_port; self-discovery based on switch type (U_Port); optional port type control
Fabric Switches supporting unicast, multicast (255 groups), and broadcast
Hot pluggable, industry-standard small form factor pluggable (SFP), LC connector; Short-Wavelength
Laser (SWL), up to 1,640 ft/500 m; Long-Wavelength Laser (LWL), up to 6.2 mi/10 km; distance
depends on fiber optic cable and port speed (optional)
Short-wave up to 1,640 ft (500 m); long-wave up to 6.2 mi (10 km) when available
Simple Name Server; Registered State Change Notification (RSCN); Alias Server (multicast); Advanced
Zoning; WebTools; Fabric Watch; ISL Trunking (optional); Advanced Performance Monitoring.
Control Processor
Control Processor
Control Processor
Control Processor
Modules
Modules
Modules
Modules
Backplane
Backplane
Backplane
Backplane
Input power
Input power
Input power
Input power
Chassis power
Chassis power
Chassis power
Chassis power
Cooling
Cooling
Cooling
Cooling
Telnet; SNMP (FE MIB, FC Management MIB); Web Tools; Fabric Watch Optional; Fabric Access layer
10/100 Ethernet (RJ-45), in-band over Fibre Channel (requires fabric); two serial ports (DB-9) per
control processor module
POST and embedded online/offline diagnostics
DA - 11384
North America — Version 13 — June 24, 2005
HP StorageWorks Core Switch 2/64 and Core Switch
HP StorageWorks Core Switch 2/64 and Core Switch
HP StorageWorks Core Switch 2/64 and Core Switch
HP StorageWorks Core Switch 2/64 and Core Switch
Redundant (active/standby) control processor modules; automatic failover;
non-disruptive software upgrades; dual-flash memory on each control
processor to store two software images
Hot swappable
Fully passive
Dual AC inputs
Four AC-DC power supply modules, 2N redundant
Three blower assembly modules (two operational required)
2/64 PowerPak B-Series Family
2/64 PowerPak B-Series Family
2/64 PowerPak B-Series Family
2/64 PowerPak B-Series Family
Page 12