HP StorageWorks Fabric OS 4.4.0f Nota di rilascio - Pagina 41

Sfoglia online o scarica il pdf Nota di rilascio per Interruttore HP StorageWorks Fabric OS 4.4.0f. HP StorageWorks Fabric OS 4.4.0f 48. Hp storageworks fabric os 4.4.0f release notes (aa-rw89a-te, october 2005)

Table 8
Fabric OS 4.4.0d closed issues summary
Closed defect
Issue: Bad RSCN from 3rd party
switch caused name server to assert
and switch panic
Symptom: kSWD: Detected
Unexpected Termination of:
''[0]nsd
Issue: Common Access Layer
Daemon (CALD) crash generated
core dump files and switch panic.
Symptom: When an overnight
script was run to disable/enable
and to change speed on E-ports,
CALD generated core dump files.
Issue: In PID Format 2 (Extended
Edge PID Format), extend the
support beyond 127 ports. In PID
Format 2 (Extend Edge PID
FORMAT), change max port
support to 256.
This change does not impact PID
format 1 (the most common used
Core PID Format). It only impacts
PID format 2 (Extended Edge PID)
Issue: Web Tools/FM displays
incorrect SCSI inquiry name for
iSCSI initiator and cannot see all
devices when launch switch is FOS
4.4.x
Symptom: When using FOS4.4.x
as launch switch, the inquiry name
for the iSCSI initiator is displayed
incorrectly as a long hex string.
Also it does not report the
hostname capable FDMI devices.
Status
Fixed
Fixed
Fixed
Fixed
Fabric OS 4.4.0f release notes
41