HP StorageWorks FC Entry Switch 8B Manuale d'uso - Pagina 15

Sfoglia online o scarica il pdf Manuale d'uso per Interruttore HP StorageWorks FC Entry Switch 8B. HP StorageWorks FC Entry Switch 8B 44. Isl trunking user's guide (version 3.0)
Anche per HP StorageWorks FC Entry Switch 8B: Manuale d'uso (44 pagine), Manuale d'uso (38 pagine), Manuale d'uso (38 pagine), Manuale d'uso (37 pagine), Manuale d'uso (30 pagine)

HP StorageWorks FC Entry Switch 8B Manuale d'uso
Saved
In Figure 3-1, the defined and effective configurations are saved to flash:
Defined
Disable Path
Enable Path
Save Path
Figure 3-1
In Figure 3-2, Config 5 is defined (created). When it is defined, it resides only in RAM. To
permanently store the new configuration and make it accessible across reboots, it must be saved to
flash memory.
This can be accomplished by:
Saving it directly to flash (the recommended method). This saves the defined and effective
configurations to flash. If there is no effective configuration, saving it will not enable a
configuration. To save a configuration, use the cfgSave command.
Enabling it. This saves the defined and effective configurations to flash. To enable a
configuration, use the cfgEnable command.
Zoning User's Guide
This is the zone configuration that was last saved. It resides in flash memory
and it is persistent.
Effective
Config 1
Config 1
Config 2
Config 3
Config 4
Config 5

Enabling a Zone Configuration

Disabled
Saved
Defined
Config 1
Config 2
Config 3
Config 4
Config 5
Effective
Config 1
3
Using Zoning
3-3