HP surestore fc 1Gb entry switch 8B Manuale - Pagina 23

Sfoglia online o scarica il pdf Manuale per Interruttore HP surestore fc 1Gb entry switch 8B. HP surestore fc 1Gb entry switch 8B 50. Fabric os procedures guide (version 3.0)

Forcing In-order Delivery of Frames

To force in-order delivery of frames during fabric topology changes:
1.
Login to the switch as the admin user.
2.
At the command line enter the following command:
iodset
Note:

Disabling In-order Delivery of Frames

To disable In-Order Delivery of frames during fabric topology changes:
1.
Login to the switch as the admin user.
2.
At the command line enter the following command:
iodreset

Displaying Help Information for a Telnet Command

To display help information about a telnet command:
1.
Login to the switch as the admin user.
2.
At the command line enter the following command:
help command
where command is the command name you would like help with.
Fabric OS Procedures Guide
This command can cause a delay in the establishment of a new path when a topology
change occurs, and should be used with care.
Basic Configuration Procedures
2
2-9