BIOMICROBICS BioBarrier 1.5 Manuale d'uso - Pagina 4

Sfoglia online o scarica il pdf Manuale d'uso per Sistema idrico BIOMICROBICS BioBarrier 1.5. BIOMICROBICS BioBarrier 1.5 7. For use with nsf/ansi std. 40 class i/std. 350 class r, ansi/nsf std. 245
Anche per BIOMICROBICS BioBarrier 1.5: Manuale di installazione (13 pagine)

to provide adequate disinfection to prevent microorganism growth in the treated reuse water storage tank and as required by applicable
codes.
If a reuse tank is required for irrigation, it shall be located after the BioBarrier® system. This tank shall also incorporate an overflow that
allows excess reuse water to be dispersed in a locally approved soil dispersal system or released into a sanitary sewer system. If a potable
water make up system is required for irrigation, it shall include a properly designed backflow preventer that meets all applicable codes.
ONGOING SERVICE
DO NOT ENTER THE SEPTIC TANK. Hazards exist in a septic system. All precautions must be followed when inspecting the system.
Keep tank openings covered at all times. Only authorized service personnel should service a septic system. Lethal gases, high voltage electricity,
and other deadly hazards associated with the system.
Only qualified service staff should open access ports and/or covers. Infectious organisms exist in a septic tank. If any contact with wastewater,
immediately wash and disinfect all exposed areas and contact personal physician. Failure to do so could result in severe sickness or death.
The BioBarrier® wastewater treatment system operates automatically and continuously. See SERVICE MANUAL for proper maintenance
procedures for the user of the BioBarrier® wastewater treatment system include keeping the vents and the blower housing clear of debris.
The homeowner should monitor the status of the system, substances introduced into the system, and the frequency of required pump-out
as determined by the service provider.
A general evaluation of a BioBarrier® system's performance can be made using some simple observations which are outlined in the
"Trouble Shooting" guide below. Normal operation of the system would include the following:
The BioBarrier
system's blower makes a constant humming noise, much like a household refrigerator. Under normal conditions,
®
SOUND
the blower should last 5+ years without need for replacement. If an unusual noise is heard, refer to the Trouble-Shooting Guide.
A musty, earthy-type of odor is normal. However, if a sewage odor (rotten egg smell) is detected, refer to the Trouble-Shooting
SMELL
Guide.
A properly loaded and operated BioBarrier
SIGHT
or suddenly changes, refer to the Trouble-Shooting Guide.
INTRODUCING SUBSTANCES INTO THE SYSTEM:
the FAST
wastewater treatment system will process most
®
waste produced by the average household, introducing large
amounts of subatances into the system may reduce the
efficiency of the system or stop the treatment process by
destroying the biomass. These substances can be grouped as:
prohibited substances and limited-use substances. Please refer
DO'S AND DON'TS"
to the "
What You Can Put Down the Drain to maximize the system's
efficiency and reduce the time period between septic tank
pump-outs.
IN GENERAL:
If a substance is harmful to humans or is anti-
biotic in nature, it should not be put into any septic system -
including BioBarrier®. If you have a question regarding the
effect of a particular substance on the BioBarrier® system, call
your Bio-Microbics service technician
NSF CERTIFIED SYSTEMS SERVICE POLICY
All NSF Standard 40, Class 1 certified wastewater treatment
systems (BioBarrier® 0.5, 1.0, 1.5) have an initial service
agreement for two years (two calls per year) included with the
system's initial purchase price. This service is performed by the
company listed on the blower housing or control panel label.
The NSF service calls ONLY cover NSF Standard 40 certified
systems. Other components of the septic system are NOT
covered.
During an NSF service call, the service company shall inspect
the blower for proper operation, visually inspect the system's
effluent for clarity, clean the blower intake and assure proper
function of the control panel. If these service calls are not

NORMAL OPERATING CONDITIONS

system will produce effluent that looks like tap water. If the effluent is turbid, opaque,
®
While
list to get familiar with
performed on your NSF certified system, or not all of the items
are checked, please call Bio-Microbics toll-free at
or
(913)422-0707.
ONGOING SERVICE
Continual service (or extended service for NSF certified systems
beyond the first two years) is available and may be purchased
through your local Bio-Microbics distributor or current service
provider. This service policy should provide the same services
as the initial NSF service policy, and perform any additional
service that may be required by local regulation.
SEASONAL/INTERMITTENT USE PROPERTIES
The BIOBARRIER® wastewater treatment system will function
normally even if wastewater does not enter the system for an
extended period of time. The power to the system should be left
on during short periods when there is no wastewater flow to the
system. Suggestions for intermittent use (Check with local
regulations before attempting): If the property is going to be
used seasonally and shut down completely for an extended
period of time (e.g. summer use only and then abandoned for
the winter), we suggest that the BioBarrier system be shut
down. The system should be re-started upon return to the
property. Your local service provider may be contacted to
perform this operation. If the property will be used on weekends
only, it is best to leave the system ON continuously throughout
the season for use until an extended period of absence is
anticipated (extended period being at least 3 weeks or more). A
slight odor may be detected for a couple of days while the
system returns to normal operation.
800-753-3278