Sfoglia online o scarica il pdf Installazione Funzionamento e manutenzione per Pompe per laghetti EasyPro PA86. EasyPro PA86 8. Rocking piston aeration systems
Maintenance Guidelines
•
Keep your compressor and intake filter clean. Any excess dust and debris
on motor or air intake may significantly shorten the life of the compressor.
•
Diffusers may need regular cleaning in certain water conditions. This may be
every two to five years.
•
Compressors may need to be rebuilt if running but no longer "pumping air."
Contact your EasyPro dealer for compressor rebuild kits.
•
If lines become frozen, a small amount of denatured alcohol can be run
down the frozen line to thaw it out. The small amount of alcohol will not
harm fish or biological processes in your pond.
After one or two years of operation, you will possibly notice a sudden drop in air
bubbles. This is a sign the compressor needs new piston cup or vanes. Rebuild
kits are available to restore like-new performance. Be sure to keep the air filter
clean. Replacement filters are available.
Kit
Part #
PA34
PA65
PA66
PA86
PA90
Prior to 2016:
PA34
PA66
PA86 (pre-2017)
Troubleshooting
Low
High
Pressure
Pressure
•
•
•
•
•
Compressor will not start
Compressor will not start
Low
High
Air Flow
Air Flow
•
•
•
•
Compressor
SRC25
SCR50
SRC50
SRC75
SRC75
ERP25
ERP50
ERP75
Compressor Troubleshooting
Compressor
Excess
Overheating
Noise
•
•
•
•
•
Diffuser Troubleshooting
Uneven
Burping
Air Flow
Bubbles Cause and Solution
•
•
•
Replacement
Filter/Element
GAF2/GAFE
GAF2/GAFE
GAF2/GAFE
GAF2/GAFE
GAF2/GAFE
ERPF1/ERPF12E
ERPF1/ERPF12E
ERPF2/ERPF12E
Cause and Solution
Dirty air filter, clean or replace
Valves closed too much, open valves
Worn piston cup, rebuild compressor
Plugged/frozen tubing, inspect and repair
Leaky tubing or check valve, inspect and repair
Wrong voltage, check power source
Miswired electrical components, check wiring
Leak in system, check connections and repair
Manifold not set correctly, adjust placement
Damaged or torn membrane, replace
Compressor issue, see above
6
Compressor
Repair Kits
SRC25K
SRC50K
SRC50K
SRC75K
SRC75K
ERP25K
ERP50K
ERP75K