Error code
Error Code
LED Ring
Error 01
Error 03
Error 05
Error 06
Red light
flickering
every 3
Error 07
seconds.
Error 08
Error 09
Error 10
Error 11
NOTE:
If the battery constantly runs for 30 days and its SOC hasn't been corrected,
6
8
9
11
LED display
Description
Hardware error
Hardware error
Hardware error
Circuit Breaker
Open
DIP difference
LMU
Disconnect(slave)
SN missing
LMU
Disconnect(master)
Software version
inconsistent
Alpha ESS Co., Ltd.
Your Smarten Energy
Over-current discharge
Cell overvoltage
Cell under voltage
Low-temperature charge
Troubleshooting
Wait for automated
recovery.
In case problem is not
resolved, call in for repair.
Close circuit breaker after
Shutting down the battery
system.
Keep consistence of DIP
switches, restart the system.
Reconnect the
communication cable
Enter the serial number,
restart the system or call in
for repair.
Reconnect the
communication cable
Call installation for repair.