MEASUREMENT CONSIDERATIONS

The EPC9084 development board has been provided with
specially designed high frequency (up to 1 GHz minimum) capable
measurement connections using MMCX connectors located at J9 & J10
with direct access to the gate signals of both the upper and lower FETs.
These nodes can be measured directly using the Tektronix IsoVu probe
shown in figure 4. Figure 5 shows typical gate waveforms measured
using the IsoVu probe.
Figure 4: Tektronix IsoVu measurement setup
This native connection between the high and low side gate-source nodes
to an IsoVu probe tip cable has less than 2 pF common mode loading
and completely eliminates ground loops due to its galvanic isolation.
These MMCX connectors (option not installed) offer a shielded coaxial
environment to the test point which minimizes noise pickup.
V
SW
G
HS
EPC – EFFICIENT POWER CONVERSION CORPORATION |
G
LS
Figure 5: Upper gate and lower gate measurements using the Tektronix IsoVu and
switch-node voltage measurement using the TPP1000 probe
WWW.EPC-CO.COM
| COPYRIGHT 2018 |
Please contact EPC for special instructions on using these connections.
To prevent an unterminated transmission line hanging on the gate it
is recommended to remove resistors R21 & R22 when not using this
feature. The maximum impedance loading of these nodes is 2.5 kΩ.
Tektronix is a leading manufacturer of power test solutions for design
validation, characterization, and performance testing. EPC partnered
with Tektronix to define the requirements for accurate measurements
on GaN devices which led to the development of the Tektronix IsoVu
measurement system. IsoVu is a galvanically isolated differential
measurement system with 1 GHz bandwidth, 1 Million to 1 (120 dB)
common mode rejection ratio, 50 V differential, and 2000 V common
mode voltage range. Previously impossible differential measurements
such as the high-side V
are now possible because of IsoVu's high
GS
common mode rejection across bandwidth.
IsoVu allows you to:
• Characterize the time alignment of high side and low side events
• Optimize and tune switching characteristics such as edge rates,
overshoot, ringing and dead time
• See the interactions due to parasitic coupling between the high and
low side transistors
• Make isolated high frequency current measurements using low
impedance sense resistors
• Improve reliability through accurate characterization across all
operating conditions
EPC would like to acknowledge Tektronix
measurement-systems) for their support of this project.