Alpha Group OutBack Power FLEXmax 80 Manuale - Pagina 3
Sfoglia online o scarica il pdf Manuale per Controllore Alpha Group OutBack Power FLEXmax 80. Alpha Group OutBack Power FLEXmax 80 8. Charge controller overview
Models:
FLEXmax 80: 80 amps maximum continuous
output current (up to 40°C without thermal derating)
FLEXmax 60: 60 amps maximum continuous
output current (up to 40°C without thermal derating)
Features:
Supports 12, 24, 36, 48, and 60 Vdc
battery voltages
Backlit display screen (LCD) with 80 characters
(4 lines, 20 characters per line)
Last 128 days of operational data logging
Voltage step-down capability allowing a higher PV
array voltage configuration
Manual and automatic equalization cycles
Screen Versions:
English
Spanish
Australian (English with different default settings)
Recommended Input PV Wattage
per Charge Controller*
Maximum PV
Maximum PV
Battery Bank
Input Wattage
Input Wattage
Voltage
for the
for the
FLEXmax 80
FLEXmax 60
12 Vdc
1000 W
750 W
24 Vdc
2000 W
1500 W
36 Vdc
3000 W
2250 W
48 Vdc
4000 W
3000 W
60 Vdc
5000 W
3750 W
*Standard Test Conditions
900-0135-01-00 Rev A.vsd\Overview\2012-03-21
©2012 OutBack Power Technologies. All Rights Reserved.
FLEXmax 80 Charge
Controller
In
23.2 V
0.0 A
LCD Screen
Out
27.6 V
0.0 A
0.000 kW
0.0 kWH
AUX:
OFF
Sleeping
Soft Keys
Terminals
PV
PV
BAT
BAT
Torque =
+
–
–
+
4 Nm (35 in-lb)
MATE
RTS
Port
Port
(RJ45)
(RJ11)
The interior design is identical in each model.
FLEXmax 60 Charge
Controller
In
23.2 V
0.0 A
Out
27.6 V
0.0 A
0.000 kW
0.0 kWH
AUX:
OFF
Sleeping
Startup Screen
OutBack
24V
Power
Systems
Charge Controller
Status Screen
PV Input Voltage
IN
23.2 V
0.0 A
PV Input Current
Battery Voltage
OUT 27.6 V
0.0 A
Output Current
Instantaneous Kilowatts
0.000 kW
0.0 kWH
Daily Accumulated
AUX: OFF
Sleeping
Kilowatt-hours
AUX Status
Mode of Operation
1
2
Advances to the
1
main menu screens
Advances to the
2
end-of-day screens
Navigation:
LCD Screen
Main Menu
Charger Aux
Light
EQ
Misc Advanced
Logging
Stats
Soft Key
EXIT
GO
Commands
Soft Key
<EXIT>,
Buttons
<GO> etc.
Soft Key Color Code:
Available menus
Select this option to proceed
Adjusts the set points value
Selects a function (e.g., ON, OFF, AUTO)
Switches between devices on the
ports of the Communications HUB
Navigation colors
NOTE: Soft key functions will vary depending on the selected
menu and are defined by the word above the key in the LCD.
Indicates a 1-screen movement within a
Menu. These are color coded according to
their function or purpose.
If accompanied by a dashed
line, pressing that soft key will
return the user to the location
identified by the dashed line.
This will vary depending on the
devices in the system.
NOTE: See page 2-4 of this guide for menu maps for setting the
versions, changing the language of the screens, and accessing
the main menu.
See the FLEXmax Series Owner's Manual for details on the
settings available in the main menu.
Page 1