Dictator 790100 Manuale tecnico - Pagina 14
Sfoglia online o scarica il pdf Manuale tecnico per Sistema di apertura della porta Dictator 790100. Dictator 790100 17. Ac-21 sliding door operators
Technical Manual
DICTAMAT AC 900-21
4) Installation of the
Final Switches
Connection Cables to the
Control System
Page 04.020.04
Installation of the DICTAMAT AC 900-21, cont.
Separate final switches are only necessary, if you have
a door operator without integrated position control
(incremental encoder).
At the most you should provide 4 final switches (opener)
(depending on the used control system):
- closed position
- position of crawling speed closing
- positon of crawling speed opening
- open position
The DICTAMAT door operator is furnished with a 2 m connection
cable to the SQUARE 940 control system.
DICTAMAT with incremental encoder:
1 motor cable,
1 cable to connect the incremental encoder,
1 cable to the brake,
1 cable to the thermal contact of the motor.
DICTAMAT for final switches:
1 motor cable,
1 cable to the brake,
1 cable to the thermal contact of the motor.
We use screened cable to eliminate any perturbations. In case you
have to lengthen the cable, please mind the advice given in the
manual of the control system. The cable is provided with cable
glands. It is already connected to the door operator (only for the
SQUARE 940 control system) and just has to be connected to
the control system. For the connection in the control system, please
see the connection diagram in the manual of the control system
(SQUARE 940).
Information on how to adjust the final positions, speed
etc. you will find in the manual of the used control
system.
© DICTATOR TECHNIK GMBH · Gutenbergstr. 9 · 86356 Neusäß · GERMANY
Tel. +49-821-24673-0 · Fax +49-821-24673-90 · E-Mail [email protected] · 1120