ALPHA PLAM ALPHA FURNACE 2014 Istruzioni per l'installazione, la regolazione e l'uso - Pagina 3
Sfoglia online o scarica il pdf Istruzioni per l'installazione, la regolazione e l'uso per Fornace ALPHA PLAM ALPHA FURNACE 2014. ALPHA PLAM ALPHA FURNACE 2014 9. Solid fuel programme
1. ALPHA FURNACE 2014 SPECIFICATIONS
- rated thermal power.......................................................................................................................11 KW
- rated efficiency................................................................................................................................76 %
- required chimney airflow ...............................................................................................................12 Pa
- width........................................................................................................................................750mm
- depth...................................................................................................................................400mm
-height...............................................................................................................................................803mm
- flue pipe diameter........................................................................................................................Ø 210mm
- the height from the floor to the axis of the flue...................................................................652mm
- combustion chamber volume..........................................................................................18dm
- rated heating power.........................................................................................................................11kNJ
- ash tray volume..................................................................................................................9 dm
- capacity to heat up the room..............................................................................................100-150m
- type of fuel, timber, lignite, brown coal
- mass.......................................................................................................................................110 kg
- regulated combustion with the option to adjust the required amounts of air using the air regulator.
10
12
1
2
3
Fig. 1
Solid fuel fireplace
1. Air regulators
2. Ash tray
3. Ash tray lid
4. Glass-middle
5. Combustion door
6. Lateral middle right side
7. Shaker
8
9
11
8 . Burner
9. Cap
10. Glass-top
11. Lateral upper right side
12. Lateral upper left side
13. Lateral lower right side
3
3
4
5
6
7
13
3