Sfoglia online o scarica il pdf Manuale d'uso per Caricabatterie Epever GM3024N. Epever GM3024N 20. Flush mount solar charger
Lead-acid Battery Voltage Parameters
Parameters are in the 12V system at 25℃, ×2 in 24V.
Item
Over Voltage Disconnect
Voltage
Charging Limit Voltage
Over Voltage Reconnect
Voltage
Equalize Charging
Voltage
Boost Charging Voltage
Float Charging Voltage
Boost Reconnect
Charging Voltage
Low Voltage Reconnect
Voltage
Under Voltage Warning
Reconnect Voltage
Under Volt. Warning Volt.
Low Volt. Disconnect Volt.
Discharging Limit Voltage
Equalize Duration
Boost Duration
(1)When the battery type is sealed, gel, flooded, the adjusting range of equalizing
duration is 0 to180min and boost duration is 10 to180min.
(2) The battery type of User should follow the rules as below when modifying the
value of parameters in user battery type (factory default value is the same as sealed
type):
a. Over Voltage Disconnect Voltage > Charging Limit Voltage ≥ Equalize Charging
Voltage ≥ Boost Charging Voltage ≥ Float Charging Voltage > Boost Reconnect
Charging Voltage.
b. Over Voltage Disconnect Voltage > Over Voltage Reconnect Voltage
c. Low Voltage Reconnect Voltage > Low Voltage Disconnect Voltage ≥ Discharging
Limit Voltage.
d. Under Voltage Warning Reconnect Voltage > Under Voltage Warning Voltage ≥
Discharging Limit Voltage.
e. Boost Reconnect Charging voltage > Low Voltage Disconnect Voltage.
BEIJING EPSOLAR TECHNOLOGY CO.,LTD.
Sealed
Gel
16.0V
16.0V
15.0V
15.0V
15.0V
15.0V
——
14.6V
14.4V
14.2V
13.8V
13.8V
13.2V
13.2V
12.6V
12.6V
12.2V
12.2V
12.0V
12.0V
11.1V
11.1V
10.6V
10.6V
——
120min.
120min.
120min.
13
Flooded
User
16.0V
9~17V
15.0V
9~17V
15.0V
9~17V
14.8V
9~17V
14.6V
9~17V
13.8V
9~17V
13.2V
9~17V
12.6V
9~17V
12.2V
9~17V
12.0V
9~17V
11.1V
9~17V
10.6V
9~17V
120min.
0~180min.
120min.
10~180min.
Table1