DieHard 200.713201 Manuale d'uso - Pagina 7

Sfoglia online o scarica il pdf Manuale d'uso per Caricabatterie DieHard 200.713201. DieHard 200.713201 16. 20/15/10/2 amp fully automatic battery charger
Anche per DieHard 200.713201: Manuale d'uso (16 pagine)

DieHard 200.713201 Manuale d'uso
Battery Type:
The charger is designed to provide a
specific
charge best suited for charging
each type of battery. Charging a GEL
CELL battery as a REGULAR
or DEEP
CYCLE battery can permanently
damage
it. Charging a battery on
anything but the proper selection can
result in a partial charge or damaged
battery. DO NOT charge a Gel Cell on
any other setting but, Gel Cell.
DEEP CYCLE
.....tl
REGULAR
GEL
CELL
Battery Voltage:
Select the voltage of your battery. The
most common applications will be 12 volt,
but 24 volt battery systems are being
widely used in special applications.
12VOLT
_
24VOLT
Charge Type:
Use the MANUAL setting only if you
check the charging progress
frequently.
The charger will not stop
charging when the battery reaches
full charge, possibly damaging the
battery if left on too long. A severely
discharged
battery may not have
enough charge to start the control
circuit in an automatic setting.
In this
case, charge on MANUAL until the
battery has enough charge to accept
an Automatic setting.
Use the AUTOMATIC setting for all
battedes and charge rates. The
charger will automatically stop
charging when the battery reaches full
charge and begin charging again when
battery requires.
Usethe MAINTAINER to maintain a
charge in batteries stored for long
periods, such as those in RVs,
seasonal farm equipment and the like.
Use after fully charging the
battery in one of the charging
positions.
MANUAL
o, I I
AUTOMATIC
_ _,_
MAINTAINER
Charge Rate:
Use the 2 AMP charge rate when you
can afford the time. The lower the
charge rate, the longer itwill take, but
the battery is subjected to much less
stress. Unless a Gel Cell battery
manufacturer recommends otherwise,
use the 2 AMP rate for charging.
Use the10 AMP 12/24 VOLT rate for
most common charging applications.
It provides the most complete charge
with the least stress on the battery.
Use the 20 AMP 12 VOLT rate when
speed is important. This rate is
selected when 12 VOLT is selected on
the Battery Voltage switch. It provides
a faster charge than the 10 AMP rate.
The 15 AMP 24 VOLT rate is selected
when 24 VOLT is selected on the
Battery Voltage switch.
10 AMP 12/24 VOLT
2,MPI ll =o,.P,2VO
12/24VOLT |1
_
I| 15 AMP24VOLT
AMMETER:
The ammeter indicates the measure
amount of amperes being drawn by the
battery. When you first start charging a
battery, the reading will be high, with
the needle near 20 using the 20 amp
charging rate.
In the MANUAL setting, as the battery
charges, the needle will fall to about 8
or 10 amps, indicating a charged
battery.
In beth AUTOMATIC
settings, the meter
needle will fall to zero when the battery
has completed the charging cycle. A
7