DieHard 28.71331 Manuale dell'operatore - Pagina 8
Sfoglia online o scarica il pdf Manuale dell'operatore per Caricabatterie DieHard 28.71331. DieHard 28.71331 9. 12v automatic battery charger & engine starter
![DieHard 28.71331 Manuale dell'operatore](/uploads/products/server2/422854/422854.jpg)
NOTE: If the engine does turn over but
never starts, there is not a problem with
the starting system; there is a problem
somewhere else with the vehicle. STOP
cranking the engine until the other problem
has been diagnosed and corrected.
AUTOMATIC CHARGING MODE
When an Automatic Charge is performed,
the charger switches to the maintain mode
automatically after the battery is charged.
ABORTED CHARGE
If charging cannot be completed normally,
charging will abort. When charging aborts,
the charger's output is shut off and the
BOOST/CHARGING (yellow/orange) LED
will flash. Do not continue attempting to
charge this battery. Have it checked or
replaced.
DESULFATION MODE
Desulfation could take 8 to 10 hours. If
desulfation fails, charging will abort and
the BOOST/CHARGING (yellow/orange)
LED will flash.
COMPLETION OF CHARGE
Charge completion is indicated by the
CHARGED/MAINTAINING (green) LED.
When pulsing, the charger has switched to
the maintain mode of operation.
BATTERY CHARGING TIMES
CCA = Cold Cranking Amps
SMALL BATTERIES
Motorcycle, garden tractor, etc.
CARS AND
TRUCKS
MARINE/DEEP-CYCLE
Times are based on a 50% discharged battery and may change, depending on age
and condition of battery.
12. MAINTENANCE AND CARE
A minimal amount of care can keep your
battery charger working properly for years.
• Clean the clamps each time you are
finished charging. Wipe off any battery
fluid that may have come in contact with
the clamps to prevent corrosion.
• Occasionally cleaning the case of the
charger with a soft cloth will keep the
finish shiny and help prevent corrosion.
RC = Reserve Capacity Ah = Amp Hour
BATTERY SIZE/RATING
200-315 CCA
315-550 CCA
550-1000 CCA
MAINTAIN MODE
(FLOAT-MODE MONITORING)
When the CHARGED/MAINTAINING
(green) LED is pulsing, the charger has
started maintain mode. In this mode, the
charger keeps the battery fully charged
by delivering a small current when
necessary. If the charger has to provide
its maximum maintain current for a
continuous 12 hour period, it will go into
abort mode (see Aborted Charge section).
This is usually caused by a drain on the
battery or the battery could be bad. Make
sure there are no loads on the battery. If
there are, remove them. If there are none,
have the battery checked or replaced.
MAINTAINING A BATTERY
The 28.71331 charges and maintains 12
volt batteries, keeping them at full charge.
NOTE: The maintain mode technology
allows you to safely charge and maintain
a healthy battery for extended periods
of time. However, problems with the
battery, electrical problems in the
vehicle, improper connections or other
unanticipated conditions could cause
excessive current draws. As such,
occasionally monitoring your battery and
the charging process is required.
6-12 Ah
12-32 Ah
40-60 RC
60-85 RC
85-190 RC
80 RC
140 RC
160 RC
180 RC
• Coil the input and output cords neatly
when storing the charger. This will help
prevent accidental damage to the cords
and charger.
• Store the charger unplugged from the AC
power outlet in an upright position.
• Store inside, in a cool, dry place. Do not
store the clamps on the handle, clipped
together, on or around metal, or clipped
to the cables.
• 8 •
CHARGE RATE/TIME
6A<>2A
1½-2½ h
2½-7 h
7½-9½ h
9½-12 h
MAINTAIN ONLY
12 h
MAINTAIN ONLY
MAINTAIN ONLY
MAINTAIN ONLY