DieHard 28.71344 Manuale dell'operatore - Pagina 7

Sfoglia online o scarica il pdf Manuale dell'operatore per Caricabatterie DieHard 28.71344. DieHard 28.71344 13. 6v/12v automatic battery charger & engine starter

11. OPERATING INSTRUCTIONS
WARNING: A spark near battery may
cause an explosion.
IMPORTANT: Do not start the vehicle with
the charger connected to the AC outlet, or
it could damage the charger.
NOTE: This charger is equipped with
an auto-start feature. Current will not be
supplied to the battery clamps until a
battery is properly connected. The clamps
will not spark if touched together.
CHARGING A BATTERY
IN THE VEHICLE
1. Turn off all the vehicle's accessories.
2. Keep the hood open.
3. Clean the battery terminals.
4. Place the charger on a dry, non-
flammable surface.
5. Lay the AC/DC cables away from any
fan blades, belts, pulleys and other
moving parts.
6. Make sure the ON/OFF switch is set
to OFF.
7. Connect the battery, following the
precautions listed in sections 6 and 7.
8. Connect the charger to an electrical
outlet.
9. Press the ON/OFF switch to turn ON.
10. When the charger starts, the display
will show DIEHARD.
11. Select the battery type and charge rate.
Charging will then begin automatically.
See section 12 for CHARGING
message details.
12. The yellow/orange LED will light, and
the display will show ANALYZING
BATTERY while the charger determines
that the battery is properly connected
and the condition of the battery.
13. When charging is complete, press the
ON/OFF switch to turn OFF, disconnect
the charger from the AC power, remove
the clamps from the vehicle's chassis,
and then remove the clamp from the
battery terminal.
CHARGING A BATTERY OUTSIDE
OF THE VEHICLE
1. Place battery in a well-ventilated area.
2. Clean the battery terminals.
3. Make sure the ON/OFF switch is set
to OFF.
4. Connect the battery, following the
precautions listed in sections 6 and 7.
5. Connect the charger to the electrical
outlet.
6. Press the ON/OFF switch to turn ON.
7. When the charger starts, the display
will show DIEHARD.
8. Select the battery type and charge rate.
Charging will then begin automatically.
See section 12 for CHARGING
message details.
9. The yellow/orange LED will light, and
the display will show ANALYZING
BATTERY while the charger determines
that the battery is properly connected
and the condition of the battery.
10. When charging is complete press the
ON/OFF switch to turn OFF, disconnect
the charger from the AC power,
disconnect the negative clamp, and
finally the positive clamp.
11. A marine (boat) battery must be
removed and charged on shore.
AUTOMATIC CHARGING MODE
When an Automatic Charge is performed,
the charger switches to the maintain mode
automatically after the battery is charged.
BATTERY CONNECTION INDICATOR
If the charger does not detect a properly
connected battery, charging will not start
and the digital display will show one
of two messages. If the display shows
CONNECT CLAMPS, make sure the
charger is connected to the battery and the
connection points are clean and making
a good connection. If the display shows
WARNING CLAMPS REVERSED, press
the ON/OFF switch to turn off, unplug
the charger from the AC outlet and then
reverse the connections at the battery.
CHARGE COMPLETION AND MAINTAIN
MODE (FLOAT MODE MONITORING)
Charge completion is indicated by the solid
green LED and the digital display showing
FULLY CHARGED AUTO MAINTAINING.
This means that the charger has stopped
charging and has switched to the Maintain
Mode of operation. NOTE: If the charger
has to provide its maximum maintain
current for a continuous 12 hour period,
it will go into Abort Mode (see Aborted
Charge section). This is usually caused by
a drain on the battery, or the battery could
be bad. Make sure there are no loads on
the battery. If there are, remove them. If
there are none, have the battery checked
or replaced.
• 7 •