Table 1
CABLE
BINDER
CABLE PAIR
TIP WIRE
PAIR
GROUP
SUB-GROUP
COLOR
GROUP
1-25
BLUE
1-5
WHITE
6-10
RED
11-15
BLACK
16-20
YELLOW
21-25
VIOLET
26-50
ORANGE
26-30
WHITE
31-35
RED
36-40
BLACK
41-45
YELLOW
46-50
VIOLET
51-75
GREEN
51-55
WHITE
56-60
RED
61-65
BLACK
66-70
YELLOW
71-75
VIOLET
76-100
BROWN
76-80
WHITE
81-85
RED
86-90
BLACK
91-95
YELLOW
96-100
VIOLET
Figure 1
TIP 1
TIP 2
NOT IN SERVICE
TIP 1
TIP 2
RING WIRE COLOR
(FOR EACH TIP
WIRE COLOR)
ST
1
WIRE-BLUE
ND
2
WIRE-ORANGE
RD
3
WIRE-GREEN
TH
4
WIRE-BROWN
TH
5
WIRE-SLATE
ST
1
WIRE-BLUE
ND
2
WIRE-ORANGE
RD
3
WIRE-GREEN
TH
4
WIRE-BROWN
TH
5
WIRE-SLATE
ST
1
WIRE-BLUE
ND
2
WIRE-ORANGE
RD
3
WIRE-GREEN
TH
4
WIRE-BROWN
TH
5
WIRE-SLATE
ST
1
WIRE-BLUE
ND
2
WIRE-ORANGE
RD
3
WIRE-GREEN
TH
4
WIRE-BROWN
TH
5
WIRE-SLATE
RING 1
RING 2
RING 1
RING 2
Terminal shall be installed to the applicable requirements of the:
National Electrical Code, ANSI/NFPA 70(Article 800, Section C)
Canadian Electrical Code, Part 1 (Section 60)
CAUTION: Risk of electric shock
Terminal is not be used without the arrester assembly installed.
TM91-0041
REV.05
2100 SERIES
INSTALLATION
PROCEDURE
(FOR INDOOR USE ONLY
Building Entrance
Terminal
2100B-6
2100BN-6
CONTENTS:
1.0
General
2.0
Terminal Module Specifications
3.0
Fuse Link Specifications
4.0
Installation Data
5.0
Installation Procedures
6.0
Grounding
7.0
Terminal Installation
8.0
Terminal Diagram
1.0
General:
The 2100B-6 & 2100BN-6 Building Entrance Terminals are
double cross – connect field, indoor protection units designed
for terminating outside plant cables. The 2100B-6 & 2100BN-6
BETs are 6 pair terminals with a QCBIX® in/QCBIX® out
configuration. Terminal pin wiring matrix is found in Table 1.
1.1
Terminal Dimensions:
Model
Height
Width
2100B-6
6.45in
5.0in
2100BN-6
6.45in
5.0in
(c/w cover)
Cable Requirements:
1.2
This BET is equipped with a fuse link; therefore it must only be
spliced with 24 gauge or physically larger gauge C.O. feeder
cable. This will ensure the highest operating conditions for the
BET.
2.0
Terminal Module Specifications:
The Terminal will accept any five-pin module of Western
Electric design.
Note: Failure to insert UL, cUL or CSA approved modules to
the full "IN" position will void the Building Entrance Terminals
UL and cUL product approval.
)
PAGE
1
1
1
2
2-3
3
3
4
Depth
3.9in
1.5in