Arch AQF600-12S Manuale di avvio rapido

Sfoglia online o scarica il pdf Manuale di avvio rapido per Alimentazione Arch AQF600-12S. Arch AQF600-12S 5. Ac-dc switching power supply

AQF600 SERIES
KEY FEATURES
 Universal Input: 90-264 VAC
 With P.F.C. Function, PF>0.95
 Remote ON/OFF Function
 Current Share Function
 Power Good Function
 High Efficiency up to 90~93%
 Protections: Over Load / Over Voltage /
.Over Temperature / Short Circuit
 High Power Density
 RoHS Compliant Design
 3-Year Product Warranty
ELECTRICAL SPECIFICATIONS
All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Model No.
Max Output Wattage (Convection)
Voltage
Frequency (Hz)
Current (Full load)
Input
Inrush Current (<2ms)
Leakage Current
Power Factor
Voltage (V.DC.)
Trim
Voltage Accuracy
Current (Convection) (A) max
Line Regulation (LL-HL) (typ.)
Output
Load Regulation (5-100%) (typ.)
Minimum Load
Maximum Capacitive Load
Ripple & Noise (max.)
Efficiency (typ.)
Hold-up Time
Over Power Protection
Over Voltage Protection
Protection
Over Temperature
Short Circuit Protection
Input-Output (V.AC)
Isolation
Input-FG
Output-FG .(V.AC)
5V Stand by (18CFM FAN)
DC OK Signal (Power Good)
Function
Remote Control
Current Share
Operating Temperature
Storage Temperature
Temperature Coefficient
Environment
Humidity
MTBF
Vibration
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
AQF600-12S
540W
(W)
90-264 VAC or 120-370 VDC
47-63 Hz
< 8.0 A max. (115 VAC) / < 3.5 A max. (230 VAC)
< 15 A max. (115 VAC) / < 30 A max. (230 VAC)
< 3.5 mA max.(240VAC 63Hz)
PF>0.99 (115 VAC) / PF>0.95 (230 VAC) at Full Load
12V
±5%
±2%
45
±1%
±1%
1%
60,000 uF
< 1% Vout
90%
12 ms min.
Auto recovery
Auto recovery
Auto recovery
Latch off
3000VAC or 4242VDC
(V.AC)
1500V
500V
5VSB: [email protected] ; Tolerance 10% , Ripple & Noise: 100m Vp-p (max.)
Turn ON: 3.7~5.7V ; Turn OFF: 0~1V
+RC / -RC: Power ON=open ; Power OFF=short
CN4:CS, +V, -V are connected mutually in parallel.
-25°C...+70°C (with derating)
-25°C...+85°C
±0.03%/°C ( 0~50°C )
95% RH
>100,000 h @ 25°C (MIL-HDBK-217F)
10~500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes.
AC-DC Switching Power Supply
AQF600-24S
AQF600-48S
600W
600W
24V
48V
25
12.5
50,000 uF
20,000 uF
92%
92%
VER :
A_8
update :
2020.08.27
600 Watts
AQF600-54S
600W
54V
11.1
10,000 uF
93%
-1-