Sfoglia online o scarica il pdf Istruzioni per il cablaggio e la programmazione per Sistema di sicurezza Digiflex Vision 64. Digiflex Vision 64 2. Alarm panel

E.g. 2:- Using a Zone: Choose any hardwired zone 1-8, Zn Dbl 9-16 can be programmed as a keyswitch.
Menu 3-1-1
Select option 13 (Key switch zone type).
Menu 3-1-8
Select option 3 (Inverted Seal) set to 'Y'.
Menu 3-4-1
Select option 05 (Pulse all On/Off) .
If using zone double (zn 9-16) the zone 1-8 on the same terminal should be an Entry/Exit zone type.
Zones 1 – 8 use 3k3 resistors
Zones 9 – 16 use 6k8 resistors
Exiting Program Mode:
Press and hold the Menu button for 2sec.
Alternatively you can select Exit and press OK from any menu levels.
Digiflex Vision 64 Keyswitch wiring & programming
Zn Doubling Table