ASC4 / ASC4EVO
4 ch × 450 W
4 ch × 250 W
20 Hz – 20 kHz
<0.1%
> 500
125 dB(A)
Unbalanced input: type RCA socket
Input sensitivity: +3 dBV (1.4 Vrms)
Input impedance: 100 k
®
4 pole Neutrik speakON
Active status: Green (ON) / Red (FAULT)
Mute status: Orange
®
Class D – ICEpower Technology
NO (ASC4)
On board (ASC4EVO)
Thermal controlled low noise fan
Side-to-side air ow
10 A @ 230 V (2300 VA)
Panel socket type C14 (IEC 60320) – 10 A
Ampli er: plug type C13 (IEC 60320) – 10 A,
Plug type IEC 7/7 hybrid,
3 conductor cable 3 × 1.0 mm
170-264 VAC - 45/65 Hz
Operation at 85-132 VAC is possible after internal modi cation.
Consult factory if needed.
Internal master fuse: type 10 A T
(time-delayed type) 6.3 × 30 mm
Each power ampli er module is protected by an independent fuse
FUSES ARE NOT USER-REPLACEABLE
437 × 88 × 466 mm (2RU – 19")
9,2 kg
ASC6 / ASC6EVO
Unbalanced input: type RCA socket
Input sensitivity: +3 dBV (1.4 Vrms)
Input impedance: 100 k
4 pole Neutrik speakON
Active status: Green (ON) / Red (FAULT)
Class D – ICEpower Technology
On board (ASHC6VO)
Thermal controlled low noise fan
16 A @ 230 V (3450 VA)
Panel socket type C20 (IEC 60320) – 16 A
Ampli er: plug type C19 (IEC 60320) – 16 A,
Plug type IEC 7/7 hybrid,
2
3 conductor cable 3 × 1.5 mm
170-264 VAC - 45/65 Hz
Operation at 85-132 VAC is possible after internal modi cation.
Consult factory if needed.
Internal master fuse: type 16 A T
(time-delayed type) 6.3 × 30 mm
Each power ampli er module is protected by an independent fuse
FUSES ARE NOT USER-REPLACEABLE
437 × 88 × 466 mm (2RU – 19")
6 ch × 450 W
6 ch × 250 W
20 Hz – 20 kHz
<0.1%
> 500
125 dB(A)
®
Mute status: Orange
®
NO (ASC6)
Side-to-side air ow
2
10 kg
11
ASD8
8 ch × 200 W
8 ch × 120 W
20 Hz – 20 kHz
<0.1%
> 500
125 dB(A)
Unbalanced input: type RCA socket
Input sensitivity: +3 dBV (1.4 Vrms)
Input impedance: 100 k
®
4 pole Neutrik speakON
Active status: Green (ON) / Red (FAULT)
Mute status: Orange
®
Class D – ICEpower Technology
NO
Thermal controlled low noise fan
Side-to-side air ow
10 A @ 230 V (3450 VA)
Panel socket type C14 (IEC 60320) – 10 A
Ampli er: plug type C13 (IEC 60320) – 10 A,
Plug type IEC 7/7 hybrid,
3 conductor cable 3 × 1.0 mm
170-264 VAC - 45/65 Hz
Operation at 85-132 VAC is possible after internal modi cation.
Consult factory if needed.
Internal master fuse: type 10 A T
(time-delayed type) 6.3 × 30 mm
Each power ampli er module is protected by an independent fuse
FUSES ARE NOT USER-REPLACEABLE
437 × 88 × 466 mm (2RU – 19")
10 kg
2