Display
REGISTER TABLE
Register
Threshold for relay 1, HIGH (#) (not used w/o relay)
Threshold for relay 1 LOW (#) (not used w/o relay
Threshold for relay 2 HIGH (#) (not used w/o relay
Threshold for relay 2 LOW (#) (not used w/o relay
Visual HIGH
Visual LOW
Impuls HIGH
Impuls LOW
Decimal N°
Preset HIGH
Preset LOW
Zero setting
Input selection
Filter debounce input
Relays mode (not used)
Time activation relays (not used)
Thresholds relays under password (not used w/o relay)
Absolute counting value HIGH (#)
Absolute counting value LOW (#)
Relative counting value HIGH (#)
Relative counting value LOW (#)
Operation Register (*)
(#) this parameter is expressed in encoder count number, then is not multiplied by
factor. The value read from serial port is equal to the display value only if
Technical Features
Power supply
Line frequency
Power absorbtion
Display
Inputs type
Encoder power supply
Count input
Input maximum frequency
Count possibility
Serial port connection
Working temperature
Relative humidity
Size (with terminal box)
Drilling template
Front case protection
Electromagnetic compatibility
Low voltage
RoHS
Manufacturer
All communications to the manufacturer should be addressed to:
FIAMA s.r.l., Via G. Di Vittorio, 5/A - 43016 San Pancrazio (Parma) - Italy
Tel. (+39) 0521.672.341 - Fax. (+39) 0521.672.537 – e-mail: [email protected] - www.fiama.it
FIAMA srl is not responsible for any damage to persons or things caused by tamperings and wrong use
and in any case that are not consistent with the features of the instrument.
Data: 13/01/16
Address Hex N° of byte register
0x00
0x01
0x02
0x03
0x04
0x05
0x06
0x07
0x08
0x09
0x0a
0x0b
0x0c
0x0d
0x0e
0x0f
0x10
0x11
0x12
0x13
0x14
0x15
115Vac, 230Vac, 24Vac, 15÷30Vdc ±10%
50/60 Hz
3 VA
–99999; 999999
Optoisolated
12Vdc (max 60mA)
Open collector NPN/PNP
Push-pull
Differential Line driver
Mechanical contact
10 KHz
Bi-directional
Monodirectional (counting up)
Monodirectional (counting down)
RS232 or RS485 MODBUS RTU protocol
0-50°C
10-90%
48x96x100 mm
45x92 mm
IP54
2014/30/EU
2014/35/EU
2011/65/EU
file: F1X5_RS_ing.doc
F1X5_RS
2 byte (HIGH byte don't care)
2 byte
2 byte (HIGH byte don't care)
2 byte
2 byte (HIGH byte don't care)
2 byte
2 byte (HIGH byte don't care)
2 byte
2 byte (HIGH byte don't care)
2 byte (HIGH byte don't care)
2 byte
2 byte (HIGH byte don't care)
2 byte (HIGH byte don't care)
2 byte (HIGH byte don't care)
2 byte (HIGH byte don't care)
2 byte (HIGH byte don't care)
2 byte (HIGH byte don't care)
2
2
2
2
2 byte (HIGH byte don't care)
/
VISUAL
IMPULS
/
=4.
VISUAL
IMPULS
correction
Pag 12/12