FAILURE
1. POWER LIGHT (Yellow) does NOT light.
2. Unit does not heat.
3. Unit gets too hot or won't shut off.
4. Blower does not work or makes noise.
5. GFCI device trips.
GFCI (ground-fault circuit interrupter): A GFCI receptacle is a device that de-energizes a circuit when it
detects an unsafe flow of current to ground. The intention of a GFCI device is to minimize the potential for an
If cause is none of the above, refer to our list of Authorized Service Centers, FL-1400
5925 Heisley Road • Mentor, OH 44060-1833
TROUBLE-SHOOTING
POSSIBLE CAUSE
1a. Switch is "OFF".
1b. Cord unplugged from wall outlet.
1c. Circuit breaker/fuse to wall outlet tripped/blown.
2a. Temperature control is set too low.
2b. Switch is "OFF".
3a. Defective electrical parts.
UNPLUG UNIT FROM WALL OUTLET.
4a. Defective blower.
5a. The insulation inside the heating element may
have absorbed some moisture. This may have
occurred if the cabinet has not been used for a long
period of time or during shipping and storage of the
cabinet. Plug the cabinet into a non-GFCI outlet and
set the temperature control to its maximum. Let the
cabinet run for about 1 hour to dry out the heating
element from any moisture may have been absorbed.
If the circuit breaker trips, call the factory Authorized
service agent. After drying the heating element, plug
cabinet into the GFCI receptacle; the cabinet should
run properly. If the GFCI device continues to trip, call
the factory Authorized service agent.
electrical shock.