Crescend Technologies C7 SERIES Manuale di installazione e assistenza - Pagina 11

Sfoglia online o scarica il pdf Manuale di installazione e assistenza per Amplificatore Crescend Technologies C7 SERIES. Crescend Technologies C7 SERIES 17. Continuous duty power amplifier

3.

GENERAL OPERATING INFORMATION

3.1.

INTRODUCTION

This section contains operating instructions for the C7 amplifier.
3.2.

LOCATION OF STATUS INDICATORS

The location and function of the C7 amplifier status indicators and is shown in Figure 3-1
and described in detail in Table 3-1.
Figure 3-1. C7 Series Status Indicators, Front Panel
Table 3-1. C7 Series Amplifier Status Indicators
STATUS LED
DC ON
Green LED. Illumination indicates DC Power has been applied.
LOW OUTPUT
Red LED. Activates when the output power drops to approximately
80-85% of set output power.
HIGH VSWR
Red LED. Activates when load VSWR exceeds approximately
2.5:1.
HIGH TEMP
Red LED. Activates when the amplifier exceeds a safe operating
temperature.
Copyright Crescend Technologies
FUNCTION
11