Cisco 9124 - mds multilayer fabric switch Nota di rilascio - Pagina 15

Sfoglia online o scarica il pdf Nota di rilascio per Interruttore Cisco 9124 - mds multilayer fabric switch. Cisco 9124 - mds multilayer fabric switch 36. Mds 9000 series
Anche per Cisco 9124 - mds multilayer fabric switch: Specifiche tecniche (2 pagine), Scheda tecnica (9 pagine), Specifiche tecniche (3 pagine), Manuale di configurazione (49 pagine), Nota di rilascio (48 pagine), Nota di rilascio (44 pagine), Nota di rilascio (22 pagine), Nota di rilascio (3 pagine), Nota di rilascio (40 pagine), Manuale (16 pagine), Manuale di installazione dell'hardware (36 pagine)

Cisco 9124 - mds multilayer fabric switch Nota di rilascio
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m .
Step 2
Change the configuration for the first port of the quad when the admin port mode is auto. (A quad is a
group of four ports, supported by a data path processor (DPP). The groups are 1 to 4, 5 to 8, 9 to 12, and
so on.) Do not leave the port mode set to auto.
Step 3
Change the configuration for ports 2, 3, and 4 of the quad:
Step 4
Save the running configuration to the startup configuration before the upgrade procedure to ensure that
the changes are preserved during and after the upgrade. To save the configuration, enter the following
command:

Upgrading the SSI Image on Your SSM

Use the following guidelines to nondisruptively upgrade the SSI image on your SSM:
OL-12208-05
Hardware is Fibre Channel, SFP is short wave laser w/o OFC (SN)
Port WWN is 20:4b:00:0d:ec:09:3c:00
Admin port mode is auto
snmp traps are enabled
Port mode is F, FCID is 0xef0300
Port vsan is 1
Speed is 2 Gbps
Transmit B2B Credit is 3
Set the port admin mode to E or Fx if the current operational port mode is E, TE, F or FL.
a.
switch# config t
switch(config)# interface fc 2/1
switch(config-if)# switchport mode fx
Set the port admin mode to E if the current operational port mode is E:
b.
switch# config t
switch(config)# interface fc 2/5
switch(config-if)# switchport mode e
a.
Set the admin port mode to Fx if the admin port mode of these ports is E, TE, or auto.
switch# config t
switch(config)# interface fc 2/2
switch(config-if)# switchport mode fx
b.
If the first port in the port group has admin mode E or if the port is operational in E port mode,
change the admin state of ports 2, 3, and 4 to shutdown.
switch# config t
switch(config)# interface fc 2/2
switch(config-if)# shutdown
switch# copy running-config startup-config
Install and configure dual supervisor modules.
SSM intelligent services traffic on SSM ports is disrupted during upgrades. Fibre Channel switching
traffic is not disrupted under the following conditions:
Upgrade the SSI boot images on the SSMs on the switch to a release version supported by your
Cisco SAN-OS release. Refer to the
Storage Service Interface
Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS Release 3.1(3)
Upgrading Your Cisco MDS SAN-OS Software Image
<-------- shows port is configured in auto mode
<-------- shows current port operational mode is F
Cisco MDS SAN-OS Release Compatibility Matrix for
Images.
15