AccuStream AccuValve On/Off Valve Manuale - Pagina 10

Sfoglia online o scarica il pdf Manuale per Unità di controllo AccuStream AccuValve On/Off Valve. AccuStream AccuValve On/Off Valve 20.

AccuStream Cutting Systems
Removing the valve body components.
1. Isolate the water pressure from the ON/OFF valve by dumping the pump pressure or closing
the manual isolation valve.
2. Turn the actuator ON and verify that there is NO water pressure.
3. With the actuator pressurized with air, unthread the adapter from the bottom of the valve body
and remove the seat from the bottom.
4. Turn the air to the actuator OFF and REMOVE the airline from the top of the actuator.
5. Unthread the actuator from the top of the valve body.
6. With the valve body still in the mounting collar, remove the seal components by using the seal
removal tool 11205 and push up through the bottom of the valve body.
7. Thoroughly wash out the interior of the Valve Body before replacing components.
NOTE: The needle guide ID may have build-up of seal material at the bottom of the .093 dia
section. After extensive use, this build-up may stop the needle from closing. If the Guide ID is
going to be re-used, it must be cleaned. A .093 drill bit can be used, to manually remove this
material.
Installing new valve body components.
1. Place the needle bearing over the needle with the needle
going through the vent hole side.
2. Place the valve seal with the o-ring side out over the end
of the needle.
3. Lubricate the o-ring on the valve seal and insert into the
top of the valve body until the needle guide is flush to t
top of the bore.
4. Thread (hand tighten) the actuator onto the top of the
valve body. Reattach air to the actuator and turn actuator
air pressure on to pull the needle valve up.
5. Apply AccuGoop to the surfaces at the top of seat and to
the surface of the seat where the needle seats.
6. Place the seat into the pilot diameter at the top of the
adapter and thread the adapter into the bottom of the
valve. Torque the adapter to the valve using the two-
wrench technique.
7. Turn off the air to the actuator.
8. Reapply high-pressure water to the valve and check for leaks.
9. Apply water pressure to the valve assembly to verify there are no leaks. Before installing the
Cutting Head quickly cycle the Valve on and off a few times to purge all contaminants.
Reinstall the Cutting Head and commence cutting.
13084 ON/OFF VALVE & CUTTING HEAD MANUAL