Digiscan Labs iPROTECT 1216 Manuale - Pagina 8

Sfoglia online o scarica il pdf Manuale per Sensori di sicurezza Digiscan Labs iPROTECT 1216. Digiscan Labs iPROTECT 1216 13. Counter surveillance 3-band rf detector

Preparation
Create any sound in the room to activate the bugging devices and mask your actions. Use a portable
speaker, radio or any other source.
Connect the antenna to the SMA socket.
Turn on the iProtect 1216 and make sure the device is in the ALL BANDS display mode with
3 bargraphs displayed.
Selecting the working mode
If the sweeping procedure is revealed, your adversary might deactivate the bugging device
making the further search harder. For fully covert operation, when it is impossible to create a
masking sound in the room, use the SILENT mode.
The AUDIO mode can be selected in order to listen to the signal's audio footprint. Thanks to
a specific sound some signals can be identified quicker.
Advice: Carry out a short training with several RF devices before applying this mode. Detect
and listen to an active cell phone, Wi-Fi access point, cordless DECT phone, etc.
The ALARM mode is very convenient since it allows the user to scan quickly without
watching the display. When the iProtect 1216 approaches the transmitter the RF level exceeds
the threshold and the device starts producing the alerting sound and shows the "ALARM"
message. Additionally the threshold helps the user to mask the interference coming from
outdoor broadcasting, communication towers or neighboring wireless devices.
To minimize false detections the alerting sound appears after the signal exceeds the threshold
during a predefined time.
Threshold
Adjust the threshold level to mask any background interference in the ALARM mode.
Use the
on the bargraphs.
8
buttons to set the threshold slightly higher than the existing RF background displayed