Parameter 150: Force calibration
By setting this parameter to 2 the device enters the calibration mode. The parameter relevant
only if the device is set to work in positioning mode (parameter 151 set to 1, 2 or 4).
Size: 1 Byte, Default Value: 0
Setting
Description
0
device is not calibrated
1
device is calibrated
2
force device calibration
Parameter 151: Operating mode
This parameter allows adjusting operation according to the connected device.
Size: 1 Byte, Default Value: 1
Setting
1
roller blind (with positioning)
2
Venetian blind (with positioning)
3
gate (without positioning)
4
gate (with positioning)
5
roller blind with built-in driver
6
roller blind with built-in driver (impulse)
Parameter 152: Venetian blind - time of full turn of the slats
For Venetian blinds (parameter 151 set to 2) the parameter determines time of full turn cycle of
the slats.
For gates (parameter 151 set to 3 or 4) the parameter determines time after which open gate will
start closing automatically (if set to 0, gate will not close).
The parameter is irrelevant for other modes.
Size: 5 Byte, Default Value: 150
Setting
0 - 90000 (0 – 900s, every 0.01s) – time of turn
Parameter 153: Set slats back to previous position
For Venetian blinds (parameter 151 set to 2) the parameter determines slats positioning in
various situations.
Description