FIBARO SWIPE FGGC-001 Manuale operativo - Pagina 7

Sfoglia online o scarica il pdf Manuale operativo per Controllore FIBARO SWIPE FGGC-001. FIBARO SWIPE FGGC-001 13. Swipe gesture controller

FIBARO SWIPE FGGC-001 Manuale operativo
12

#8: Sequences of gestures

Sequences:
user can create sequences of two or three gestures to expand num-
ber of possible actions. Every sequence is saved in its advanced pa-
rameter (no. 31-36) with 16 bits, every basic gesture is identified with
4 bits.
Gesture values:
Ges-
value 4 bits
ture
Size
4 bits
0
0000 empty
1
0001
/\
Purpose
reserved
2
0010
\/
Example
none
3
0011
<
Example:
always
4
0100
>
binary values
0000
Example:
always 0
i
decimal values
NOTE
In case of sequence of
two gesture, field for
third gesture should
Rules of creating sequences:
be set to 0.
Maximum of six sequences can be created.
Each sequence must be unique.
Sequence can consist of two or three basic gestures (left, right, up
or down).
Two identical gestures cannot be used next to each other.
Learning a new sequence:
To perform automatic learning of a sequence:
1. Change value of parameter 30 to number of sequence slot you
want to fill (1 to 6).
2. Wake up the device using 1st menu position (see "Operating the
device" on page 10)
3. The device will enter learning mode, which is signalled by con-
stant beeping.
4. Perform a desired sequence.
SEquEnCES OF GESTuRES
Bit mask of parameter
Overall
4 bits
4 bits
4 bits
16 bits
first
second
third
gesture
gesture
gesture
/\
>
<
0001
0100
0011
1 * 256
4 * 16
3 * 1
sum = 323
Creating and configuring sequences in the Home Center interface:
1. Go to the device options by clicking the icon on its bar:
2. Drag and drop two or three gestures to create a desired sequence.
3. Confirm the selection by clicking "Confirm a new sequence".
4. Wake up the device using 1st menu position (see "Operating the
device" on page 10).
5. Click the plus icon ("new Reaction") next to the newly created se-
quence.
6. Select the device you want to control.
7. From the available options select the reaction of the controlled
device and complete the setup by clicking "Save".
Creating and editing sequences manually:
To manually create or edit a sequence slot:
1. Calculate new value of parameter using table and formula:
Value of parameter = 256 * Value of first gesture +
+ 16 * Value of second gesture + Value of third gesture
2. Change the value of corresponding parameter (parameters 31 to
36 for slots 1 to 6).
13
i
NOTE
Setting parameter to
0 will delete the se-
quence.
SEquEnCES OF GESTuRES