9.0. ARMING TEST-CONTROL
With the control panel disarmed (OFF), proceed as follows:
Digit any one of the memorized
codes (example 1, 2 and 3). On
the display 3 asterisks will appear.
Press the button
The control panel emits one beep. On the
display the message on the right appears.
The writing "ON" and the LED "UNIT ON"
will flash quickly. The LED "TEST" will
light and remains so until the control panel is disarmed.
Before the writing "delay" appears, press
the button
The writing "TEST" will appear and it will
flash quickly.
After a few seconds the writing "delay"
that indicates a 60 seconds exit time will
appear.
At the end of the exit time, the writing
"delay" disappears and both the writing
"TEST" and the LED "UNIT ON" from
flashing become fixed. The control panel is
armed in Test-Control Day mode.
If while arming there are zones triggered
or unbalanced not by-passed, or control
panel has low battery, the writing "TEST"
on the display and the LED "ON" will flash
slowly during the exit time.
Furthermore, the message "zone in alarm" or "battery centr." will appear.
If a few zones are by-passed, during the
exit time on the display will appear the
message "zone by-p" instead of "delay".
To verify the zones by-passed, proceed as
indicated on the points 3) and 4) of the
paragraph 7.0.
Violation of one or more zones provokes the appea-
rance of a flashing message on the display. Keep in
mind that only the alarm with the highest priority level
is visualized entirely on the display and remains in
memory until the control panel is re-armed.
To verify if there have been other alarm events,
access the menu by pressing the button "FORWARD".
Next to each zone that has triggered an alarm a dot
will appear that flashes slowly (see on the right).
Digit-KD instruction manual
(DAY mode)
to confirm.
.
ENGLISH
OFF
OK
***
ON
OK
TEST
OK
TEST
delay
OK
TEST
OK
TEST
delay
zone in alarm
TEST
zone by-p
OK
TEST
hold-up
wire
TEST
1
2
OK
3
4
"zone 3" has triggered an alarm
Pag. 9