Sharp SJ-47L-A2G Manuale di servizio - Pagina 9
Sfoglia online o scarica il pdf Manuale di servizio per Frigorifero Sharp SJ-47L-A2G. Sharp SJ-47L-A2G 32.
ITEMS
Thermostat
Defrost thermostat
Thermo. fuse
Fan motor
Defrost heater
Door switch
Damper thermostat
Defrost timer
Lamp socket
Lamp
Compressor
Starting relay
Overload relay(Protector) 1.8C36A1
Running capatior
LIST OF ELECTRICAL PARTS
TYPE NAME
MM1-8149
125V 6A
250V 3A
S101
250V 8A
SF70E
250V 10A
3R00121A
220-240V 50/60Hz
MM6-4264
220-240V 378Ω
DSD-5
250V 0.25A
MM1-6173
—
ND1004M2
220-240V
50/60Hz
—
250V 1A
—
240V 15W
FL1568SD
220-240V/50Hz
PET0SAT
—
—
—
420V or 450V 4µF
RATING
(At normal notch)
ON/OFF : -20 / -25˚C
Open/Close : 8 / 1˚C
Working temp. : 70˚C
Working with ø100 fan
140W at 230V
4 terminals push-button type
Open/Close : 5 / 0˚C
Integration type
Cycle time : 10h44m/8h57m(50/60Hz)
Delay time : 4m20s/3m37s(50/60Hz)
E-12(Hard plastic body type)
E-12
Cooling capacity : 188W (50Hz)
Main coil : 13.3Ω
Aux. coil : 25.6Ω
(at 25˚C)
22 Ω 300V
Open/ Close : 130/60˚C
—
9
SJ-43L-A2
SJ-47L-A2
SPECIFICATIONS
Common
Aux. coil
Main coil