Amendment to the Function Manual
5.1 "Order Creation" interface
● OrderCategory (Out)
– Name of the order category which is selected.
● OrderName (Out)
– Name of the order which is to be created.
● OrderNameIsAvailable (Out)
– Indicates whether the selected order name already exists in SIMATIC BATCH or not.
● OrderDescription(Out)
– Description of the order which is to be created.
● OrderSize (Out)
– Selected amount of the order
● OrderSplitMode (Out)
– Selected order split mode
● MinBatchSize (Out)
– Selected minimum batch size
● MaxBatchSize (Out)
– Selected maximum batch size
● NumberOfBatches (Out)
– Selected number of batches
● BatchesSize (Out)
– Selected size of batches
● RemainingBatchSize (Out)
– Selected size of the remaining batch
● OrderCreationMode (Out)
– Selected order Creation Mode
● OrderStartTime (Out)
– Selected Order Start Time
● BatchesWaitingTime (Out)
– Selected Batches Waiting time
● SelectedBatch (In)
– Sets the index in the batch list for getting or setting batch data with subsequent
– Restricted to 1 to Number of batches
– Defaulted to 1
34
"SelectedBatch ..." properties.
Note
This is independent from operator selection!
Advanced Process Functions SIMATIC BATCH Integration