Siemens SIMATIC RTLS5201T Manuale di istruzioni per l'uso - Pagina 16

Sfoglia online o scarica il pdf Manuale di istruzioni per l'uso per Apparecchiature industriali Siemens SIMATIC RTLS5201T. Siemens SIMATIC RTLS5201T 30. Localization systems

Installation and operation
3.2 Operation
Step 1: Adapt transponders of the RTLS4000 product family
• In the "Localization configuration" client, change UWB channel 2 to UWB channel 5.
• Change the "PRF" parameter (parameter name and parameter value) as follows:
– PRF: DW_PRF = DW_enePRF_64_MHz
– Code: DW_PreamblCode = DW_enePreamblCode_10
• Restart the transponder or reset it via "Reset" as follows:
The parameters can be configured via a trained commissioning engineer in the Locating
Manger.
– Red frame: Change the UWB channel to UWB channel 5 and then click the "Set" button.
– Green frame: For the "DW_PRF" parameter, enter the value "DW_enePRF_64Mhz" and
– Green frame: For the "DW_PreamblCode" parameter, enter the value
– Blue frame: Click the "Reset" button and ensure that the "State" has the "Configured" value.
16
then click the "Set" button.
"DW_enePreamblCode_10" and then click the "Set" button.
All configurations have thereby been adopted.
Operating Instructions, 08/2023, C79000-G8976-C687-02
SIMATIC RTLS5201T